Appendix 2. Cable
2.4 G020/G021/G022 Cable
170
2.4 G020/G021/G022 Cable
Cable type: G020/G021/G022 cable
Application: Manual pulse generator (5V power supply type)
1ch
MPG
2ch
3ch
1
2
7
9
3
4
8
11
5
6
13
1HA
1HB
+5V
0V
2HA
2HB
+5V
0V
3HA
3HB
0V
FG
MPG
Connector
: CDA-15P
Contact
: CD-PC-111x11
Case
: HDA-CTH
Recommended manufacturer:
Hirose Electric
Connector name
: MPG
Crimp terminal
:V1.25-3x12
Recommended
manufacturer
:JST
Wire material
Recommended manufacturer
(Note) Fold the cable shield over the sheath,
and wrap copper foil tape over it.
Connect the wound copper foil tape to
the connector's GND plate.
1ch
Cable name
G020 cable
G021 cable
G022 cable
2ch
3ch
Precautions
The circles indicate the used channel.
: B-22(19)U x 2SJ-1 x 9
: Sumitomo Electric Industries
2.5 G023/G024 Cable
Cable type: G023/G024 cable
Application: Manual pulse generator (5V power supply type)
ENC
Connector : 10120-3000VE
Case : 10320-52F0-008
Recommended manufacturer : 3M
Wire material:UL1061-2464 AWG24 x 6P
Recommended manufacturer : Oki Electric Cable
Crimp terminal:V1.25-3 x 8
Recommended manufacturer:JST
Manual pulse generator cable channel
1 2
G023 cable
G024 cable
: Usable channel
Control unit
(Connect to ENC
connector)
(Note) Fold the cable shield over the sheath, and wrap copper foil tape over it.
Connect the wound copper foil tape to the connector's GND plate.
8
18
10
5
7
17
20
15
1HA
1HB
5VDC
GND
2HA
2HB
5VDC
GND
1ch
2ch
FG
ENC
ENC