6. Connections of Control Unit
6.7 Connecting with Auxiliary Axis Servo Drive Unit: MR-J2-CT
63
6.7 Connecting with Auxiliary Axis Servo Drive Unit: MR-J2-CT
(1) Connect auxiliary axis servo drive unit MR-J2-CT to the connector SV1, SV2.
MITSUBISHI
SV1
NC control unit
Auxiliary axis
servo drive unit
(MR-J2-CT)
CN1A
CN1B
CN1A
CN1B
SV2
Auxiliary axis
servo drive unit
(MR-J2-CT)
CN1A
CN1B
CN1A
CN1B
SH21 cable
SH21 cable
Auxiliary axis
servo drive unit
(MR-J2-CT)
Auxiliary axis
servo drive unit
(MR-J2-CT)
<Related items>
Cable drawing: "Appendix 2 (SH21 Cable)"