4. Outline Drawing
4.9 Grounding Plate and Clamp Fitting
39
4.9 Grounding Plate and Clamp Fitting
The shield wire generally only needs to
be grounded to the connector's case frame.
However, the effect can be improved by
directly grounding to the grounding plate as
shown on the right.
Install the grounding plate near each unit.
Peel part of the cable sheath as shown on
the right to expose the shield sheath. Press
that section against the grounding plate with
the clamp fitting. Note that if the cable is thin,
several can be clamped together.
Install the grounding plate directly onto the
cabinet or connect a grounding wire so that
sufficient frame grounding is achieved.
Parts name
Model
Remark
Grounding plate D
With two clamp fittings A
Grounding plate
Grounding plate E
With one clamp fitting B
Clamp set A
Clamp fittings A, holding parts and fitting threads are enclosed
Clamp set
Clamp set B
Clamp fitting B, holding parts and fitting threads are enclosed
Outline drawing
11
35
6
22
35
A
C
24
0
-0
.2
17.5
6
3
7
B±
0.
3
Grounding plate
2-ø5 hole
Installation hole
Note 1
M4 screw
MAX L
10
24
+0
.3
0
30
Clamp fitting
A
B
C
L
Grounding plate D
100
86
30
Clamp fitting A
70
Grounding plate E
70
56
–
Clamp fitting B
45
(Note 1)
Screw hole for wiring to cabinet's grounding plate
(Note 2)
The grounding plate thickness is 1.6mm
40
Cable
Clamp fitting
(Fitting A, B)
Grounding plate
Clamp section drawing