6. Connections of Control Unit
6.9 Connecting with RS-232C Device
68
6.9 Connecting with RS-232C Device
(1) Connect RS-232C device to the connector SIO.
MITSUBIS
HI
SIO
NC control unit
RS-232C device
F035 cable
Cable name
1ch
2ch
F034 cable
F035 cable
[SIO]
Connector
: 10120-3000VE
Case
: 10320-52F0-008
Recommended
manufacturer
: 3M
[1ch] [2ch]
Connector : CDB-25S
Contact
: CD-SC-111
Lock nut
Recommended
manufacturer
Wire material
: UL1061-2464 AWG22
×
12P
Recommended
manufacturer
: Oki Electric Cable
SIO
1ch
FG
12
2
13
3
14
4
16
6
1
17
7
18
8
19
9
20
10
11
SD1(TXD1)
RD1(RXD1)
RS1(RTS1)
CS1(CTS1)
ER1(DTR1)
DR1(DSR1)
0V
SD2(TXD2)
RD2(RXD2)
RS2(RTS2)
CS2(CTS2)
ER2(DTR2)
DR2(DSR2)
0V
2
3
4
5
20
6
8
9
7
2
3
4
5
20
6
8
9
7
2ch
: Hirose Electric
: HD-LNA
Reserved
Reserved
Reserved
Reserved
(Note)
Please be aware that the wiring of serial communication cable (G031/G032 cable) for a display unit
differs.
<Related items>
Cable drawing: "Appendix 2 (F034/F035 Cable)"
Connector pin assignment: "Appendix 3 (SIO-NC connector)"