OVERVIEW OF UNITS
2-1. SYSTEM CONSTRUCTION
Model
Capacity
Cassette Ceiling
Ceiling
Concealed
Wall
Mounted
Ceiling
Suspended
Floor standing
Ceiling
concealed Lossnay
Air to
Water
unit
*2
2 by 2
4-way flow
2-way flow 1-way flow
Exposed Concealed Fresh air
*3
PLFY-P
PLFY-P PLFY-EP
*7 PLFY-M
PLFY-P PMFY-P
PEFY-P
PEFY-M
PKFY-P PCFY-P
PFFY-P
PFFY-P
PEFY-P
GUF
*6
PWFY-P
10
–
–
–
–
–
–
–
–
10VLM-E
–
–
–
–
–
–
15
15VFM-E
–
–
–
–
–
15VMS1(L)-E
–
15VLM-E
–
–
–
–
–
–
20
20VFM-E 20VEM-E
–
20VEM-E 20VLMD-E 20VBM-E
20VMS1(L)-E
20VMA(L)-E(2/3)
20VMR-E-L/R
20VMA(L)-A 20VLM-E
–
20VLEM-E
20VKM-E
20VLRM-E
20VLRMM-E
20VCM-E
–
–
–
25
25VFM-E 25VEM-E
–
25VEM-E 25VLMD-E 25VBM-E
25VMS1(L)-E
25VMA(L)-E(2/3)
25VMR-E-L/R
25VMA3-E
*5
25VMA(L)-A 25VLM-E
–
25VLEM-E
25VKM-E
25VLRM-E
25VLRMM-E
25VCM-E
–
–
–
32
32VFM-E 32VEM-E
32VEM-A
–
32VEM-E 32VLMD-E 32VBM-E
32VMS1(L)-E
32VMA(L)-E(2/3)
32VMR-E-L/R
32VMA3-E
*5
32VMA(L)-A 32VLM-E
–
32VLEM-E
32VKM-E
32VLRM-E
32VLRMM-E
32VCM-E
–
–
–
40
40VFM-E 40VEM-E
40VEM-A
–
40VEM-E 40VLMD-E 40VBM-E
40VMS1(L)-E
40VMA(L)-E(2/3)
40VMHS-E
40VMA3-E
*5
40VMA(L)-A 40VLM-E 40VKM-E 40VLEM-E
40VKM-E
40VLRM-E
40VLRMM-E
40VCM-E
–
–
–
50
50VFM-E 50VEM-E
50VEM-A 50VEM-E 50VEM-E 50VLMD-E
–
50VMS1(L)-E
50VMA(L)-E(2/3)
50VMHS-E
50VMA(L)-A 50VLM-E
–
50VLEM-E
50VLRM-E
50VLRMM-E
50VCM-E
–
50RD(H)4
–
63
–
63VEM-E
63VEM-A 63VEM-E 63VEM-E 63VLMD-E
–
63VMS1(L)-E
63VMA(L)-E(2/3)
63VMH-E
63VMA(L)-A 63VKM-E 63VKM-E 63VLEM-E
63VLRM-E
63VLRMM-E
63VCM-E
–
–
–
71
–
–
–
–
–
–
71VMA(L)-E(2/3)
71VMHS-E
71VMA(L)-A
–
–
–
–
–
–
–
80
–
80VEM-E
80VEM-A 80VEM-E 80VEM-E 80VLMD-E
–
80VMA(L)-E(2/3)
80VMH-E
80VMA(L)-A
–
–
–
–
80VMH-
E-F
–
100
–
100VEM-E
100VEM-A
–
100VEM-E 100VLMD-E
–
100VMA(L)-E(2/3)
100VMHS-E
100VMA(L)-A 100VKM-E 100VKM-E
–
–
–
100RD(H)4
100VM-
E1-AU
100VM-
E2-AU
125
–
125VEM-E
125VEM-A
–
125VEM-E 125VLMD-E
–
125VMA(L)-E(2/3)
125VMHS-E
125VMA(L)-A
–
125VKM-E
–
–
125VMHS-
E-F
–
140
–
–
–
–
–
–
140VMA(L)-E(2/3)
140VMHS-E
140VMA(L)-A
–
–
–
–
140VMH-
E-F
–
Notes:
Only for R1/R2 models: PEFY-P·VMA(L)-E3, PKFY-P·VLM, PFFY-P·VCM
Only for R2 models: PLFY-M·VEM, PEFY-M·VMA(L), PEFY-P·VMHS-E-F
M series remote
controller
Outdoor unit
4HP
5HP
6HP
PUMY-P112VKM4(-BS)
PUMY-P112YKM4(-BS)
PUMY-P112YKME4(-BS)
PUMY-P125VKM4(-BS)
PUMY-P125YKM4(-BS)
PUMY-P125YKME4(-BS)
PUMY-P140VKM4(-BS)
PUMY-P140YKM4(-BS)
PUMY-P140YKME4(-BS)
Applicable
indoor unit
Capacity
Type 10 to Type 140
Number of units
1 to 9 unit
1 to 10 unit
1 to 12 unit
Total system capacity range
50 to 130% of outdoor unit capacity
*1 *2
CMY-Y62-G-E
CMY-Y64-G-E
CMY-Y68-G-E
Branching pipe
components
Branch header
(2 branches)
Branch header
(4 branches)
Branch header
(8 branches)
Remote
controller
Name
M-NET remote controller
MA remote controller
Model number
PAR-U02MEDA
PAR-40MAA
PAR-W21MAA(when using PWFY)
Functions
• A handy remote controller for use in
conjunction with the Melans centralized
management system.
• Addresses must be set.
• Addresses setting is not necessary.
*1
. When the indoor unit of Fresh Air type is connected with the outdoor unit, the maximum connectable total indoor unit capacity is 110%.
*2
. When connecting PWFY series (Note that the connection is not allowed inside EU countries.)
• Only 1 PWFY-P100VM-E-AU can be connected. PWFY-P200VM-E-AU and PWFY-P100VM-E-BU cannot be connected.
• The PWFY unit cannot be the only unit connected to an outdoor unit. Select an indoor unit so that the total rated capacity of the indoor
units, excluding the PWFY unit, is 50 to 100% of the outdoor unit capacity.
*3
. PUMY is connectable to Fresh Air type indoor unit.
It is possible to connect 1 Fresh Air type indoor unit to 1 outdoor unit. (1:1 system)
Operating temperature range (outdoor temperature) for fresh air type indoor units differ from other indoor units.
Refer to "2-4-(3). Operating temperature range".
*4
. When connecting the CONNECTION KIT (PAC-LV11M-J) and an M-series indoor unit, refer to the installation manual for the CONNECTION KIT.
*5
. Authorized connectable indoor units are as follows;
PUMY-P112: PEFY-P25VMA3-E × 2 + PEFY-P32VMA3-E × 2
PUMY-P125: PEFY-P32VMA3-E × 4
PUMY-P140: PEFY-P32VMA3-E × 3 + PEFY-P40VMA3-E × 1
*6
. Do not connect Lossnay remote controller(s). (PZ-61DR-E, PZ-60DR-E, PZ-52SF-E, PZ-43SMF-E)
*7
. For the PLFY-EP
・
VEM-E, up to 2 units can be connected. Other indoor units excluding the PEFY-P
・
VMA3-E and PEFY-P
・
VMH(S)-E-F can be
connected within the total rated capacity and maximum number of connected units.
CONNECTION KIT
PAC-LV11M-J
M series indoor unit
*4
MSZ-SF
·
VA/VE series
MSZ-EF
·
VE/VG(K) series
MSZ-FH
·
VE series
MFZ-KJ
·
VE series
MFZ-KT
·
VG series
MFXZ-KW
·
VG series
MSZ-LN
·
VG(2) series
MSZ-AP
·
VG(K) series
MSZ-AP
·
VF series