17
OCH673D
<Heating>
15
16
17
18
19
20
21
22
23
24
25
26
27
0.6
0.7
0.8
0.9
1.0
1.1
1.2
Ratio of heating capacity
Indoor Temperature [°CD.B.]
Ratio of heating capacity
Outdoor Temperature [°C W.B.]
20°C D.B
-20.0
-15.0
-10.0
-5.0
0.0
5.0
10.0
15.0
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
Ratio of power input
Outdoor Temperature [°C W.B.]
Indoor Temperature
-20.0
-15.0
-10.0
-5.0
0.0
5.0
10.0
15.0
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
25°C D.B
15°C D.B
20°C D.B
Figure 9 Indoor unit temperature correction
To be used to correct indoor unit capacity only
Figure 10 Outdoor unit temperature correction
To be used to correct outdoor unit capacity only