OPERATING PROCEDURE
PHOTOS/FIGURES
(6)
Remove 2 electrical parts box fixing screws (4 ×
10) and detach the electrical parts box by pulling it
upward. The electrical parts box is fixed with 2 hooks
on the left and 1 hook on the right.
Photo 5
4. Removing the thermistor <Suction pipe> (TH6)
(1)
Remove the service panel. (See Photo 1)
(2)
Remove the top panel. (See Photo 1)
(3)
Disconnect the connectors, TH6 and TH7 (red), on
the Outdoor multi controller circuit board in the electri-
cal parts box.
(4)
Loosen the wire clamps on top of the electrical parts
box.
(5)
Pull out the thermistor <Suction pipe> (TH6) from the
sensor holder.
Note: When replacing thermistor <Suction pipe> (TH6),
replace it together with thermistor <Ambient> (TH7)
since they are combined together.
Refer to procedure No.5 below to remove thermis
-
tor <Ambient> (TH7).
Photo 6
Photo 7
5. Removing the thermistor <Ambient> (TH7)
(1)
Remove the service panel. (See Photo 1)
(2)
Remove the top panel. (See Photo 1)
(3)
Disconnect the connector TH7 (red) on the outdoor
multi controller circuit board in the electrical parts box.
(4)
Loosen the wire clamps on top of the electrical parts
box. (See Photo 6.)
(5)
Pull out the thermistor <Ambient> (TH7) from the sen-
sor holder.
Note: When replacing thermistor <Ambient> (TH7),
replace it together with thermistor <Suction pipe>
(TH6), since they are combined together.
Refer to procedure No.4 above to remove thermis
-
tor <Suction pipe> (TH6).
Photo 8
From the previous page.
Electrical parts box
Hooks
Hook
Electrical parts
box fixing
screws
Electrical parts box
Clamps
Thermistor
<Suction pipe> (TH6)
Thermistor
<Compressor> (TH4)
Ball valve
and stop
valve fixing
screws
Thermistor
<HIC pipe>
(TH2)
Compressor (MC)
Ball valve and stop valve
fixing screws
Lead wire of thermistor <Ambient> (TH7)
Sensor holder
154
OCH673D
Содержание CITY MULTI
Страница 35: ...35 OCH673D PUMY P112YKME4 BS R2 PUMY P125YKME4 BS R2 PUMY P140YKME4 BS R2 ...