Parameter list (by parameter number)
16
269
E023
Parameter for manufacturer setting. Do not set.
270
R342
Acceleration/deceleration time
during stall condition
0 to 3600 s
0.1 s
15 s
271
R537
Second acceleration time for
inertia compensation
0 to 3600 s
0.1 s
15 s
272
R538
Second deceleration time for
inertia compensation
0 to 3600 s
0.1 s
15 s
276
R400
Line speed monitoring reference
0 to 6553.4 m/min
0.1 m/min
1000 m/min
278
R051
Actual line speed voltage/
current gain
0 to 100%, 9999
0.1%
9999
279
R052
Actual line speed gain
0 to 6553.4 m/min
,
9999
0.1 m/min
9999
280
R053
Actual line speed voltage/
current bias
0 to 100%, 9999
0.1%
9999
281
R054
Actual line speed bias
0 to 6553.4 m/min
,
9999
0.1 m/min
9999
282
R055
Actual line speed pulse input
bias
0 to 500, 9999
0.01
9999
283
R056
Actual line speed pulse input
gain
0 to 500, 9999
0.01
9999
284
R057
Actual line speed input filter
time constant
0 to 5 s
0.01 s
0.02 s
285
A107
Overspeed detection frequency
0 to 30 Hz, 9999
0.01 Hz
9999
H416
Speed deviation excess
detection frequency
286
G400
Droop gain
0 to 100%
0.1%
0%
287
G401
Droop filter time constant
0 to 1 s
0.01 s
0.3 s
288
G402
Droop function activation
selection
0, 1, 2, 10, 11, 20 to 22
1
0
289
M431
Inverter output terminal filter
5 to 50 ms, 9999
1 ms
9999
290
M044
Monitor negative output
selection
0 to 7
1
0
291
D100
Pulse train I/O selection
[FM type]
0, 1, 10, 11, 20, 21, 100
1
0
[AM type]
0, 1
294
A785
UV avoidance voltage gain
0 to 200%
0.1%
100%
295
E201
Frequency change increment
amount setting
0, 0.01, 0.10, 1.00, 10.00
0.01
0
296
E410
Password lock level
0 to 6, 99, 100 to 106,
199, 9999
1
9999
297
E411
Password lock/unlock
(0 to 5), 1000 to 9998,
9999
1
9999
298
A711
Frequency search gain
0 to 32767, 9999
1
9999
299
A701
Rotation direction detection
selection at restarting
0, 1, 9999
1
0
331
N030
RS-485 communication station
number
0 to 31 (0 to 247)
1
0
332
N031
RS-485 communication speed
3, 6, 12, 24, 48, 96, 192,
384, 576, 768, 1152
1
96
333
─
RS-485 communication stop bit
length / data length
0, 1, 10, 11
1
1
N032
RS-485 communication data
length
0, 1
1
0
N033
RS-485 communication stop bit
length
0, 1
1
1
334
N034
RS-485 communication parity
check selection
0 to 2
1
2
335
N035
RS-485 communication retry
count
0 to 10, 9999
1
1
336
N036
RS-485 communication check
time interval
0 to 999.8 s, 9999
0.1 s
0 s
337
N037
RS-485 communication waiting
time setting
0 to 150 ms, 9999
1 ms
9999
338
D010
Communication operation
command source
0, 1
1
0
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increments
Initial value Refer
to
page