Parameter list (by parameter number)
21
2
653
G410
Speed smoothing control
0 to 200%
0.1%
0
─
654
G411
Speed smoothing cutoff
frequency
0 to 120 Hz
0.01
20 Hz
─
655
M530
Analog remote output selection
0, 1, 10, 11
1
0
─
656
M531
Analog remote output 1
800 to 1200%
0.1%
1000%
─
657
M532
Analog remote output 2
0.1%
1000%
─
658
M533
Analog remote output 3
0.1%
1000%
─
659
M534
Analog remote output 4
0.1%
1000%
─
663
M060
Control circuit temperature
signal output level
0 to 100°C
1°C
0°C
─
665
G125
Regeneration avoidance
frequency gain
0 to 200%
0.1%
100%
─
668
A786
Power failure stop frequency
gain
0 to 200%
0.1%
100%
─
673
G060
SF-PR slip amount adjustment
operation selection
2, 4, 6, 9999
1
9999
─
674
G061
SF-PR slip amount adjustment
gain
0 to 500%
0.1%
100%
─
675
A805
User parameter auto storage
function selection
1, 9999
1
9999
─
679
G420
Second droop gain
0 to 100%, 9999
0.1%
9999
─
680
G421
Second droop filter time
constant
0 to 1 s, 9999
0.01 s
9999
─
681
G422
Second droop function
activation selection
0, 1, 2, 10, 11, 20 to 22,
9999
1
9999
─
682
G423
Second droop break point gain
0.1 to 100%, 9999
0.1%
9999
─
683
G424
Second droop break point
torque
0.1 to 100%, 9999
0.1%
9999
─
684
C000
Tuning data unit switchover
0, 1
1
0
─
686
E712
Maintenance timer 2
0 (1 to 9998)
1
0
─
687
E713
Maintenance timer 2 warning
output set time
0 to 9998, 9999
1
9999
─
688
E714
Maintenance timer 3
0 (1 to 9998)
1
0
─
689
E715
Maintenance timer 3 warning
output set time
0 to 9998, 9999
1
9999
─
690
H881
Deceleration check time
0 to 3600 s, 9999
0.1 s
1 s
─
692
H011
Second free thermal reduction
frequency 1
0 to 590 Hz, 9999
0.01 Hz
9999
─
693
H012
Second free thermal reduction
ratio 1
1 to 100%
1%
100%
─
694
H013
Second free thermal reduction
frequency 2
0 to 590 Hz, 9999
0.01 Hz
9999
─
695
H014
Second free thermal reduction
ratio 2
1 to 100%
1%
100%
─
696
H015
Second free thermal reduction
frequency 3
0 to 590 Hz, 9999
0.01 Hz
9999
─
699
T740
Input terminal filter
5 to 50 ms, 9999
1 ms
9999
─
707
C107
Motor inertia (integer)
10 to 999, 9999
1
9999
─
724
C108
Motor inertia (exponent)
0 to 7, 9999
1
9999
─
744
C207
Second motor inertia (integer)
10 to 999, 9999
1
9999
─
745
C208
Second motor inertia (exponent)
0 to 7, 9999
1
9999
─
753
R539
Empty reel inertia (integer)
10 to 999, 9999
1
9999
754
R540
Empty reel inertia (exponent)
0 to 7, 101 to 104, 9999
1
9999
755
M610
Cumulative pulse clear signal
selection
0 to 3
1
0
─
756
M611
Cumulative pulse division
scaling factor
1 to 16384
1
1
─
757
M612
Control terminal option-
Cumulative pulse division
scaling factor
1 to 16384
1
1
─
758
M613
Cumulative pulse storage
0 to 3
1
0
─
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increments
Initial value Refer
to
page
Customer
setting
FM
CA
Содержание A800 Plus Series