Parameters (functions) and instruction codes under different control methods
220
134
PID differential time
22
A2
1
×
×
135
Integral clamp (positive polarity)
23
A3
1
×
×
136
Integral clamp (negative polarity)
24
A4
1
×
×
137
PID upper/lower limit hysteresis
width
25
A5
1
×
×
140
Backlash acceleration stopping
frequency
28
A8
1
141
Backlash acceleration stopping time
29
A9
1
142
Backlash deceleration stopping
frequency
2A
AA
1
143
Backlash deceleration stopping time
2B
AB
1
144
Speed setting switchover
2C
AC
1
145
PU display language selection
2D
AD
1
×
×
147
Acceleration/deceleration time
switching frequency
2F
AF
1
148
Stall prevention level at 0 V input
30
B0
1
×
×
×
×
149
Stall prevention level at 10 V input
31
B1
1
×
×
×
×
150
Output current detection level
32
B2
1
151
Output current detection signal delay
time
33
B3
1
152
Zero current detection level
34
B4
1
153
Zero current detection time
35
B5
1
154
Voltage reduction selection during
stall prevention operation
36
B6
1
×
×
×
×
155
RT signal function validity condition
selection
37
B7
1
×
×
156
Stall prevention operation selection
38
B8
1
×
×
157
OL signal output timer
39
B9
1
158
AM terminal function selection
3A
BA
1
159
DA1 output sign selection
3B
BB
1
160
User group read selection
00
80
2
161
Frequency setting/key lock operation
selection
01
81
2
×
162
Automatic restart after instantaneous
power failure selection
02
82
2
163
First cushion time for restart
03
83
2
×
×
×
×
164
First cushion voltage for restart
04
84
2
×
×
×
×
165
Stall prevention operation level for
restart
05
85
2
×
×
×
×
166
Output current detection signal
retention time
06
86
2
167
Output current detection operation
selection
07
87
2
168
Parameter for manufacturer setting. Do not set.
169
170
Watt-hour meter clear
0A
8A
2
×
171
Operation hour meter clear
0B
8B
2
×
×
×
172
User group registered display/batch
clear
0C
8C
2
×
×
×
173
User group registration
0D
8D
2
×
×
×
174
User group clear
0E
8E
2
×
×
×
178
STF terminal function selection
12
92
2
×
179
STR terminal function selection
13
93
2
×
180
RL terminal function selection
14
94
2
×
181
RM terminal function selection
15
95
2
×
182
RH terminal function selection
16
96
2
×
Pr.
Name
Instruction
code
∗1
Control method
∗2
Parameter
Re
ad
Wr
it
e
Extended
Copy
∗3
Clear
∗3
All clea
r
∗3
Speed
con
tro
l
To
rq
u
e
con
tro
l
Speed
con
tro
l
To
rq
u
e
con
tro
l
V/FV
/
F
V/F
Magnetic fluxM
ag
ne
tic
fl
ux
Magnetic flux
Vector
Vector
Vector
Sensorless
Sensorless
Sensorless
Содержание A800 Plus Series