Tension sensorless torque control details
122
TENSION SENSORLESS TORQUE CONTROL
• Set parameters according to the requirement because the torque direction for winding/unwinding differs for each device.
The setting examples are shown in the following table.
When switching between the upper winding and lower winding, set
Pr.1114
= "1" to switch between the STF and STR
signals. (Even when
Pr.1114
= "0", switching between the upper winding and lower winding is enabled by changing the
Pr.1072
setting.)
System setting
Parameter setting
Motor Installation
orientation
Material position
Winding/unwinding movement when the start
command is input
Pr.1114
Pr.1072
STF signal ON
STR signal ON
Right side
Upper winding/unwinding
0
0
Lower winding/unwinding
1
Upper winding/unwinding
Lower winding/unwinding
1
0
Lower winding/unwinding
Upper winding/unwinding
1
Left side
Upper winding/unwinding
0
1
Lower winding/unwinding
0
Upper winding/unwinding
Lower winding/unwinding
1
1
Lower winding/unwinding
Upper winding/unwinding
0
Motor
Shaft rotation
direction during
forward motor
rotation
Shaft
Содержание A800 Plus Series
Страница 240: ...239 MEMO ...