7
WIRING
2.1.2 Standard model (source logic)
For footnotes *1 to *10 refer to next page.
M
MCCB
MC
R/L1
P1
P/+
PR N/-
S/L2
T/L3
U
V
W
STR
STF
RH
RM
RL
MRS
SD
FU
RUN
SE
A
B
C
FM
SD
+
-
2
10(+5V)
2
3
1
4
(+)
(-)
5
R
RES
(-)
(+)
AM
5
4
2
I
V
S1
S2
24V
SO
SOC
MCCB
MC
R/L1
S/L2
SINK
SOURCE
SINK
SOURCE
PC
Main circuit terminal
Control circuit terminal
Earth
(Ground)
Earth (Ground)
Three-phase
AC power
supply
Main circuit
Control circuit
Control input signals (No voltage input allowed)
*2
Forward
rotation start
Reverse
rotation start
High
speed
Middle
speed
Low
speed
Multi-speed selection
Output
shutoff
circuit
Output stop
Reset
Frequency setting signals (Analog)
Terminal 4 input
(Current input)
0 to 5VDC
4 to 20mADC
0 to 10VDC
0 to 20mADC
0 to 5VDC
0 to 10VDC
PU
connector
Connector for plug-in option
connection
Analog signal output
Relay output
(Fault output)
Running
Frequency detection
Open collector output common
Sink/source common
Safety stop signal
Safety monitor output
Indicator
(Frequency meter, etc.)
Frequency setting
potentiometer
½ W, 1 k
*5
Open collector output
*9
Relay output
*8
Voltage/current
input switch
(Analog common)
Brake unit
(option)
Single-phase power input
Motor
DC reactor
(FR-HEL)
USB mini B
connector
Earth
(Ground)
24VDC power supply
(Contact input common)
Shorting wire
Safety stop input (Channel 1)
Safety stop input (Channel 2)
Safety stop input common
Option connector
(0 to ±10VDC)
Output signal: Pulse (for the inverter with
terminal FM)
Output signal: Analog (for the inverter with terminal AM)
Common for
external power supply transistor
Output signal: Pulse or analog selectable
Calibration
resistor
Moving-coil type
1mA full-scale
*4
*7
Single-phase
AC power
supply
Safety monitor output common