48
PARAMETER LIST
570
Multiple rating
setting [3-phase]
1, 2
2
571
Holding time at a
start
0 to 10 s, 9999
9999
574
Second motor online
auto tuning
0, 1
0
575
Output interruption
detection time
0 to 3600 s,
9999
1 s
576
Output interruption
detection level
0 to 590 Hz
0 Hz
577
Output interruption
cancel level
900% to 1100%
1000%
592
Traverse function
selection
0 to 2
0
593
Maximum amplitude
amount
0% to 25%
10%
594
Amplitude
compensation
amount during
deceleration
0% to 50%
10%
595
Amplitude
compensation
amount during
acceleration
0% to 50%
10%
596
Amplitude
acceleration time
0.1 to 3600 s
5 s
597
Amplitude
deceleration time
0.1 to 3600 s
5 s
Parameter 600 to 699
Para-
meter
Name
Setting Range
Initial
Value
*1
600
First free thermal
reduction frequency
1
0 to 590 Hz,
9999
9999
601
First free thermal
reduction ratio 1
1% to 100%
100%
602
First free thermal
reduction frequency
2
0 to 590 Hz,
9999
9999
603
First free thermal
reduction ratio 2
1% to 100%
100%
604
First free thermal
reduction frequency
3
0 to 590 Hz,
9999
9999
607
Motor permissible
load level
110% to 250%
150%
608
Second motor
permissible load
level
110% to 250%,
9999
9999
609
PID set point/
deviation input
selection
2 to 5
2
610
PID measured value
input selection
2 to 5
3
611
Acceleration time at
a restart
0 to 3600 s,
9999
9999
631
Inverter output fault
detection enable/
disable selection
0, 1
0
639
Brake opening
current selection
0, 1
0
640
Brake operation
frequency selection
0, 1
0
Para-
meter
Name
Setting Range
Initial
Value
*1
653
Speed smoothing
control
0% to 200%
0%
654
Speed smoothing
cutoff frequency
0 to 120 Hz
20 Hz
660
Increased magnetic
excitation
deceleration
operation selection
0, 1
0
661
Magnetic excitation
increase rate
0% to 40%,
9999
9999
662
Increased magnetic
excitation current
level
0% to 200%
100%
665
Regeneration
avoidance frequency
gain
0% to 200%
100%
673
SF-PR slip amount
adjustment
operation selection
[200/400 V class]
2, 4, 6, 9999
9999
674
SF-PR slip amount
adjustment gain
[200/400 V class]
0% to 500%
100%
675
User parameter auto
storage function
selection
1, 9999
9999
690
Deceleration check
time
0 to 3600 s,
9999
1 s
692
Second free thermal
reduction frequency
1
0 to 590 Hz,
9999
9999
693
Second free thermal
reduction ratio 1
1% to 100%
100%
694
Second free thermal
reduction frequency
2
0 to 590 Hz,
9999
9999
695
Second free thermal
reduction ratio 2
1% to 100%
100%
696
Second free thermal
reduction frequency
3
0 to 590 Hz,
9999
9999
698
Speed control D gain
0% to 100%
0%
699
Input terminal filter
5 to 50 ms,
9999
9999
Parameter 700 to 799
Para-
meter
Name
Setting Range
Initial
Value
*1
702
Maximum motor
frequency
0 to 400 Hz,
9999
9999
706
Induced voltage
constant (phi f)
0 to 5000 mV
(rad/s), 9999
9999
707
Motor inertia
(integer)
10 to 999, 9999
9999
711
Motor Ld decay ratio
0% to 100%,
9999
9999
712
Motor Lq decay ratio
0% to 100%,
9999
9999
717
Starting resistance
tuning compensation
coefficient 1
0% to 200%,
9999
9999
720
Starting resistance
tuning compensation
coefficient
2
0% to 200%,
9999
9999
Para-
meter
Name
Setting Range
Initial
Value
*1
Содержание 800 Series
Страница 10: ...4 INSTALLATION AND INSTRUCTIONS ...
Страница 46: ...40 BASIC OPERATION ...
Страница 64: ...58 INVERTER FAULT AND ALARM INDICATIONS ...
Страница 70: ...64 SPECIFICATIONS ...