2
INSTALLATION AND INSTRUCTIONS
l
E: The output specification for monitoring and the rated frequency are shown for the standard model and the
communication protocol group is shown for the Ethernet model and the safety communication model. The control logic
is fixed to the source logic for the safety communication model.
*1
The initial status of the control logic differs depending on the inverter model.
Sink logic for the models indicated with the rated capacity (kW)
Source logic for the models indicated with the rated current (A).
l
F: Availability of circuit board coating / plated conductors is shown.
*1
Conforming to IEC 60721-3-3 3C2
*2
Applicable for the FR-E820-0470(11K) or higher, and the FR-E840-0230(11K) or higher.
1.2 Accessory
l
Fan cover fixing screws
These screws are necessary for compliance with the EU Directives. For details, refer to the document enclosed with the
product.
1.3 How to read the SERIAL number
Symbol
Monitoring/protocol specifications
Rated frequency
(initial setting)
Control logic
Input signal
(initial status)
Safety stop
signal
-1
Pulse (terminal FM)
60 Hz
Sink logic
Source logic
(fixed)
-4
Voltage (terminal AM)
50 Hz
Source logic
-5
Voltage (terminal AM)
60 Hz
Sink logic
PA
Protocol group A (CC-Link IE TSN, CC-Link IE Field Network
Basic, MODBUS/TCP, EtherNet/IP, and BACnet/IP)
60 Hz
Sink logic
PB
Protocol group B (CC-Link IE TSN, CC-Link IE Field Network
Basic, MODBUS/TCP, PROFINET)
50 Hz
Sink logic/Source
logic
*1
Symbol
Circuit board coating
*1
Plated conductor
None
Without coating
Without plated conductors
-60
With coating
Without plated conductors
-06
*2
With coating
With plated conductors
CAUTION
l
In this Instruction Manual, the inverter model name consists of the inverter rated current and the applicable motor capacity.
(Example) FR-E820-0008(0.1K)
Capacity
Screw size (mm)
Quantity
FR-E820-0080(1.5K) to FR-E820-0330(7.5K),
FR-E840-0016(0.4K) to FR-E840-0170(7.5K),
FR-E820S-0080(1.5K) or higher
M3 × 35
1
FR-E820-0470(11K), FR-E820-0600(15K),
FR-E840-0230(11K), FR-E840-0300(15K)
M3 × 35
2
FR-E820-0760(18.5K) or higher, FR-E840-0380(18.5K) or higher
M3 × 50
2
The SERIAL consists of two symbols, three characters indicating the produc-
tion year and month, and six characters indicating the control number.
The last two digits of the production year are indicated as the Year, and the
Month is indicated by 1 to 9, X (October), Y (November), or Z (December).
Rating plate example
Symbol
Year Month
Control number
SERIAL
Содержание 800 Series
Страница 10: ...4 INSTALLATION AND INSTRUCTIONS ...
Страница 46: ...40 BASIC OPERATION ...
Страница 64: ...58 INVERTER FAULT AND ALARM INDICATIONS ...
Страница 70: ...64 SPECIFICATIONS ...