53
PARAMETER LIST
1445
IP filter address 4
(Ethernet)
[E800-(SC)E]
0 to 255
0
1446
IP filter address 2
range specification
(Ethernet)
[E800-(SC)E]
0 to 255, 9999
9999
1447
IP filter address 3
range specification
(Ethernet)
[E800-(SC)E]
0 to 255, 9999
9999
1448
IP filter address 4
range specification
(Ethernet)
[E800-(SC)E]
0 to 255, 9999
9999
1449
Ethernet command
source selection IP
address 1
[E800-(SC)E]
0 to 255
0
1450
Ethernet command
source selection IP
address 2
[E800-(SC)E]
0 to 255
0
1451
Ethernet command
source selection IP
address 3
[E800-(SC)E]
0 to 255
0
1452
Ethernet command
source selection IP
address 4
[E800-(SC)E]
0 to 255
0
1453
Ethernet command
source selection IP
address 3 range
specification
[E800-(SC)E]
0 to 255, 9999
9999
1454
Ethernet command
source selection IP
address 4 range
specification
[E800-(SC)E]
0 to 255, 9999
9999
1455
Keepalive time
[E800-(SC)E]
1 to 7200 s
60 s
1456
Network diagnosis
selection
[E800-(SC)E]
0 to 2, 9999
9999
1457
Extended setting for
Ethernet signal loss
detection function
selection
[E800-(SC)E]
0 to 3, 8888,
9999
9999
1480
Load characteristics
measurement mode
0, 1 (2 to 5, 81
to 85)
0
1481
Load characteristics
load reference 1
0% to 400%,
8888, 9999
9999
1482
Load characteristics
load reference 2
0% to 400%,
8888, 9999
9999
1483
Load characteristics
load reference 3
0% to 400%,
8888, 9999
9999
1484
Load characteristics
load reference 4
0% to 400%,
8888, 9999
9999
1485
Load characteristics
load reference 5
0% to 400%,
8888, 9999
9999
1486
Load characteristics
maximum frequency
0 to 590 Hz
Gr.1: 60 Hz
Gr.2: 50 Hz
1487
Load characteristics
minimum frequency
0 to 590 Hz
6 Hz
Para-
meter
Name
Setting Range
Initial
Value
*1
1488
Upper limit warning
detection width
0% to 400%,
9999
20%
1489
Lower limit warning
detection width
0% to 400%,
9999
20%
1490
Upper limit fault
detection width
0% to 400%,
9999
9999
1491
Lower limit fault
detection width
0% to 400%,
9999
9999
1492
Load status
detection signal
delay time / load
reference
measurement
waiting time
0 to 60 s
1 s
1499
Parameter for manufacturer setting. Do not set.
Alphabet (calibration parameters, etc.)
Para-
meter
Name
Setting Range
Initial
Value
*1
C0
(900)
*5
FM terminal
calibration [E800-1]
—
—
C1
(901)
*5
AM terminal
calibration
[E800-4][E800-5]
—
—
C2
(902)
*5
Terminal 2 frequency
setting bias
frequency
0 to 590 Hz
0 Hz
C3
(902)
*5
Terminal 2 frequency
setting bias
0% to 300%
0%
125
(903)
*5
Terminal 2 frequency
setting gain
frequency
0 to 590 Hz
Gr.1: 60 Hz
Gr.2: 50 Hz
C4
(903)
*5
Terminal 2 frequency
setting gain
0% to 300%
100%
C5
(904)
*5
Terminal 4 frequency
setting bias
frequency
0 to 590 Hz
0 Hz
C6
(904)
*5
Terminal 4 frequency
setting bias
0% to 300%
20%
126
(905)
*5
Terminal 4 frequency
setting gain
frequency
0 to 590 Hz
Gr.1: 60 Hz
Gr.2: 50 Hz
C7
(905)
*5
Terminal 4 frequency
setting gain
0% to 300%
100%
C38
(932)
*5
Terminal 4 bias
command (torque/
magnetic flux)
0% to 400%
0%
C39
(932)
*5
Terminal 4 bias
(torque/magnetic flux)
0% to 300%
0%
C40
(933)
*5
Terminal 4 gain
command (torque/
magnetic flux)
0% to 400%
150%
C41
(933)
*5
Terminal 4 gain
(torque/magnetic
flux)
0% to 300%
100%
C42
(934)
*5
PID display bias
coefficient
0 to 500, 9999
9999
C43
(934)
*5
PID display bias
analog value
0% to 300%
20%
Para-
meter
Name
Setting Range
Initial
Value
*1