TA7102 Hardware Installation
27
153/1531-ANF 901 14 B 2017-03-08
LED Patterns
– Default Behaviour
When no specific condition matches those described in Table 5, the LEDs behave individually according
to the following rules:
Table 6: Default LED Behaviour
LED Type
Condition
Behaviour
Power
RestartInProgress
Blinking, 1 Hz, 50% duty
RestartCompleted
Steady ON
ETH
Network traffic
Blinking, variable rate
No network traffic
Steady ON
In Use
Lines Idle and Unlocked
Steady OFF
Lines InUse and Unlocked Steady ON
Shutting Down
Steady yellow
Locked
Blinking yellow, 1 Hz, 50% duty
Ready
All lines are enabled
(operational state).
Steady ON
All lines are disabled
(operational state).
Steady OFF
At least one line is enabled
and at least one line is
disabled (operational
state).
Blink 0.25 Hz 75%
4.3
RESET/DEFAULT BUTTON
The
RESET/DEFAULT
button allows you to:
Cancel an action that was started.
Revert to known factory settings if the TA7102 refuses to work properly for any reason or the
connection to the network is lost.
Reconfigure a unit.
At Run-Time
The
RESET/DEFAULT
button can be used at run-time
– you can press the button while the TA7102
is running without powering the unit off. Table 7 describes the actions you can perform in this case.
Содержание TA7102
Страница 1: ...Mitel TA7102 INSTALLATION GUIDE...
Страница 12: ...TA7102 Hardware Installation 12 153 1531 ANF 901 14 B 2017 03 08 5 Power connector External 12 Vdc power supply...
Страница 43: ...TA7102 Hardware Installation 43 153 1531 ANF 901 14 B 2017 03 08 QoS ToS DiffServ 802 1p 802 1Q...
Страница 53: ...TA7102 Hardware Installation 153 1531 ANF 901 14 B 2017 03 08 53...