UpdateFailed
Triggered after a failure of a firmware
pack download operation. After 4
seconds, the unit restarts.
All LEDs:
• blinking at 3Hz,
• 50% duty. One LED out
of two has a 180 degree
phase. This pattern lasts
for 8 seconds.
Rescue Network
Enabled
Triggered after the user has performed a
partial reset procedure.
Power
and
In Use
LEDs:
•
blinking
(synchronized)
1Hz, 75% duty
BootOnRecoveryBank
Triggered when the unit is booting on the
recovery bank and no update is pending.
Power LED:
• blinking, 0.25Hz,
75% duty
Automatic network
configuration in progress
Waiting for DHCP (IPv4 or IPv6) answer
or IPv6 router advertisement or PPPoE
connection.
All LEDs:
• Blinking green,
3Hz, 50% duty
No network address set
Triggered when the unit cannot be
contacted because DHCP failed, PPP
failed, and no static interface is
configured.
Power LED:
• blinking, 3 Hz, 50%
duty.
NetworkRescue
The unit tries to download and install a
firmware given by the Network Rescue
server.