TA7102 Hardware Installation
153/1531-ANF 901 14 B 2017-03-08
Partial Reset
The Partial reset provides a way to contact the TA7102 in a known and static state while keeping most of
the configuration unchanged.
Following a partial reset, the TA7102 management interface is set to the
Rescue
interface. The default
address for this interface is 192.168.0.1/24 and has its corresponding link-local IPv6 available and printed
on the sticker under the TA7102. Any existing network interface that conflicts with the Rescue interface
address is disabled.
You can contact the TA7102 at this address to access its configuration parameters. It is not advised to
access the unit on a regular basis through the
Rescue
network interface. You should reconfigure the
unit’s network interfaces as soon as possible in order to access it through another interface. See
After a
Partial Reset
for more details.
In a partial reset, the following services and parameters are also affected:
4AAA service: User(s) from profile are restored with their factory password.
SNMP service: Resets the
enableSnmpV1
,
enableSnmpV2
,
enableSnmpV3
and
snmpPort
values to their default values.
WEB service: Resets the
serverPort
to its default value.
To trigger the Partial Reset:
Insert a small, unbent paper clip into the
RESET/DEFAULT
hole located at the rear of the TA7102.
While pressing the
RESET/DEFAULT
button, restart the unit. Do not depress before all the LEDs
start blinking (between 7-11 seconds).
Release the paper clip.
After a Partial Reset
Following a partial reset, you should:
Create or activate network interfaces as described in the
Software Configuration Guide
, Chapter
Interface Parameters
, Section
Interfaces Configuration
. Do not disable the
Rescue
interface!
Change the TA7102 system management network interface to something other than Rescue as
described in the
Software Configuration Guide
, Chapter
Miscellaneous
– Management Interface
,
Section
Management Interface Configuration
. Note that you must be able to contact the interface you
select in order to continue with the following steps.
Contact the TA7102 through the new system management network interface.
Disable the
Rescue
network interface as described in the
Software Configuration Guide
, Chapter
Interface Parameters
, Section
Interfaces Configuration
.
Factory Reset