69
ELECTRIC WIRE ROPE HOIST
XM SERIES
4. OPERATION AND MAINTENANCE INSTRUCTIONS
Electric system
• eliminate any condensation inside the motors
sucking it from the open terminal boxes; dry blow
with air;
• check the brakes for the integrity and function.
Restore the proper air gap;
• check the limit switches for integrity and function;
• verify the integrity of the parts and of the electric and
electronic components. Eliminate any condensation,
wipe dry the contacts of the electromagnetic
switches and protect all components with a suitable
spray for electrical equipment. Carefully clean and
apply a film of Vaseline on the closure surfaces and
threaded covers of all containers;
• perform an electric strength test at 2000 V, taking
care to isolate any rectifier bridge or electronic
circuit;
• check the trailing cables for smooth running;
• carefully check the function of the keypad.
4.14 DISPOSAL/SCRAPPING
If the hoist/trolley have to be scrapped, their parts
must be disposed of in different ways according to the
different characteristics thereof (e.g. metal, oils and
lubricants, plastic and rubber, etc.), possibly entrusting
specialised authorised disposal companies, and in any
case observing the law requirements for the disposal
of solid industrial waste.
4.12 REMOVAL - NEW DESTINATION
Should it become necessary to remove
the trolley/hoist from its working position
for extraordinary maintenance operations
(repairs/replacements), or to install it in a new
location, reverse the procedures described
under "Mounting", section 3.5 on page 16 and
sections 3.6-3.7 on page 18.
This operation must be carried out by
specialists and specially trained staff, with
adequate tools and personal safety devices,
as required by the standards.
Should the user sell the trolley/hoist to another
user (resale of used machine to third person) it
is advisable to inform the manufacturer of the
new destination and address of the new user, so
MISIA srl can send updated information, if any,
in connection to the hoist and/ or this manual.
4.13 RESTORATION AFTER STORAGE
Before putting in service a trolley/hoist which has been
stored for a long time, the following steps must be
carried out:
Mechanism
• check for any lubricant leaks and replace any faulty
seal;
• top up the lubricants;
• check that the mechanisms are properly fastened to
the structure;
• remove any trace of rust from the sliding parts of the
control devices;
• check the rope for integrity and clean and lubricate
it, the pulley grooves and the drums;
• lubricate the thrust bearing of the hooks, and
the unpainted mechanical components (shafts,
couplings, control rods);
• eliminate water deposits in hollow components of
the structure and of the mechanism.
Содержание XM SERIES
Страница 2: ......
Страница 71: ...71 Manual for installation operation and maintenance of the wire rope hoists XM Series NOTE ...
Страница 72: ...72 Manual for installation operation and maintenance of the wire rope hoists XM Series NOTE ...
Страница 73: ...73 Manual for installation operation and maintenance of the wire rope hoists XM Series NOTE ...
Страница 74: ...74 Manual for installation operation and maintenance of the wire rope hoists XM Series NOTE ...
Страница 75: ......