ELECTRIC WIRE ROPE HOIST
XM SERIES
4. OPERATION AND MAINTENANCE INSTRUCTIONS
trim 1
set 1 set 2
led 1
red
led 1
green
led 2
green
led 2
red
trim 2
QUICK GUIDE TO LIMITER ADJUSTMENT (FIG. G / DETAIL 2)
The MISIA load limiter is pre-calibrated with two levels:
Threshold 1 = 110% (rated load +10%)
Threshold 2 = 125% (rated load +25%)
During the hoist installation phase, precision calibration may be necessary before testing.
Apply the sample weight (rated load) and proceed as follows:
1) List the load and check the intervention levels are correct.
2) If the intervention level is not exact:
2a) turn the trimmer (1 or 2 according to the thresholds) in an anti-clockwise direction if the limiter does not activate
2b) turn the trimmer (1 or 2 according to the thresholds) in a clockwise direction if the limiter activates before one of the two thresholds is reached.
3) In both cases, ignore the green led (green led 1 or green led 2 according to the thresholds) which flash to indicate the modification in progress.
4) Continue to turn in the pre-selected direction until the red led switches off (red led 1 or red led 2 according to the thresholds) and wait for the
green led (green led 1 or green led 2 according to the thresholds) stops flashing.
5) With the red led off, press the “set” key for approximately 5” (set 1 or set 2 according to the thresholds) and wait for the green led (green led
1 or green led 2 according to the thresholds) to stop flashing.
6) Let the load off and start from point 1) to test the new settings.
Num. Terminal box
load cell
1
+ Cell power supply (pos.)
2
+ Signal (pos.)
3
- Signal (neg.)
4
- Cell power supply (neg.)
Num. Terminal box
relay power supply
5
+POWER 10-30 Vdc / 24 Vac
6
GND / 24 Vac
7
Relay 1 NO
8
Relay 1 NC
9
Relay 1 COM
10
Relay 2 NO
11
Relay 2 NC
12
Relay 2 COM
Num. Overload limiter
terminal board
1
+ Feeding chip (pos.)
2
+ Signal (pos.)
3
- Signal (neg.)
4
- Chips feeding (neg.)
5
+ Signal 2 (pos.)
6
- Signal 2 (neg.)
Num. Relè terminal
board feeding
7
+ Feeding 10-30 Vdc/Vac
8
GND / Vac
9
Block relè (NA)
10
Block relè (NC)
11
Block relè (COM)
12
Pre-alarm relè (NA)
13
Pre-alarm relè (NC)
14
Pre-alarm relè (COM)
15
Alarm relè (COM)
16
Alarm relè (NA)
DSET 22 CONNECTIONS
DSET 01 CONNECTIONS
Trimmer
set
Block
Threshold 2
Trimmer
set
Block
Threshold 1
Dip
switch
Threshold
Led
block
Pre-alarm
threshold
Led
Status
Led
Trimmer
filter
Button
Block
SET 2
Button
Block
SET 1
Block Relè Led
Red Led 2
Pre alarm Relè Led
Red Led 1
Alarm Relè
Feeding motor
terminal board
block and relè
Pre-alarm Relè
Block Relè
Alarm Led Relè
Monitor connector /
Monitor Programm
Overload limiter
terminal board
Содержание XM SERIES
Страница 2: ......
Страница 71: ...71 Manual for installation operation and maintenance of the wire rope hoists XM Series NOTE ...
Страница 72: ...72 Manual for installation operation and maintenance of the wire rope hoists XM Series NOTE ...
Страница 73: ...73 Manual for installation operation and maintenance of the wire rope hoists XM Series NOTE ...
Страница 74: ...74 Manual for installation operation and maintenance of the wire rope hoists XM Series NOTE ...
Страница 75: ......