102
24-3.
Anchoring the sensor cable
Use the cable anchoring tube provided with the sensor to anchor the sensor in the hole, and take great
care not to damage the cable such as by trapping it when assembling the mold.
The tube can be inserted into a 4 mm wide hole.
Anchor the sensor at a position approximately 15 mm from the sensor, as positioning the tube
immediately next to the sensor will cause it to lift up and prevent it from being maintained parallel with the
ejector pin.
In the case of the LSMS-1T-S06 and LSMS-3T-S06, the cable is too thick to be inserted into the cable
anchoring tube, and so should be anchored by pressing down into the groove using the anchoring tube.
24-4.
Vertically positioning the ejector plate
Positioning pins should be inserted between the upper and lower ejector plates to maintain the ejector pin
and sensor axes constant. If the contact between the ejector pin and sensor differs each time the mold is
disassembled, this will cause inconsistencies in the measurement results.
Slit
Silicone
(Outer diameter
4.2 mm, length 12 mm)
Ejector plate (Lower)
12 mm
4 mm
Anchoring tube
Ejector plate (Lower)
Ejector plate (Lower)
15 mm
Ejector plate (Lower)
Anchoring tube
Содержание MPC-201-25
Страница 1: ...Molding Pressure Conversion Module MPC 201 25 Instruction Manual EN294 1697G ...
Страница 2: ......
Страница 14: ...XII ...
Страница 18: ...XVI 24 4 Vertically positioning the ejector plate 102 24 5 Removing a sensor 103 ...
Страница 33: ...15 3 Right click to display the context menu and select Properties ...
Страница 34: ...16 4 Click on Update Driver in the Driver tab 5 Select Browse my computer for driver software ...
Страница 43: ...25 5 Overlay screen 6 Trend Peak Pressure screen 7 Trend Integral screen ...
Страница 54: ...36 Reset scale 1 Right click on the graph to be reset to its original scale 2 Click to select Reset scale ...
Страница 122: ......
Страница 123: ......