13
Operation
• Single cycle automatically returns travel to the reverse limit
switch location.
1. Press the forward pushbutton for
forward motor rotation.
2. Motor rotates in the forward
direction until the forward limit
switch opens.
3. The motor stops and dwells when the
forward limit switch opens. Set the
dwell time by calibrating the DWELL
TIME trimpot (see page 23).
4. Motor rotates in the reverse
direction until the reverse limit
switch opens.
5. The motor stops when the reverse
limit switch opens. Return to step 1
to repeat the process.
Press
FWD
to go forward.
Reverse
Limit
Switch
Forward
Limit
Switch
Forward Direction
Reverse Direction
STOP
AND
DWELL
STOP
Limit switch operating modes
The following is a description of the four limit switch operating modes.
Mode 1 – Half cycle between forward and reverse limit switches
1. Press the forward pushbutton for
forward motor rotation.
2. Motor rotates in the forward direction
until the forward limit switch opens.
3. The motor stops when the forward
limit switch opens.
4. Press the reverse pushbutton for
reverse motor rotation
5. Motor rotates in the reverse direction
until the reverse limit switch opens.
6. The motor stops when the reverse
limit switch opens. Return to step 1
to repeat the process
Press
FWD
to go forward.
Reverse
Limit
Switch
Forward
Limit
Switch
Forward Direction
Reverse Direction
STOP
STOP
Press
REV
to go reverse.
250-0234 rev 1.qxd 3/12/99 11:14 AM Page 13
Содержание RG501A
Страница 8: ...vi 250 0234 rev 1 qxd 3 12 99 11 14 AM Page vi...
Страница 10: ...2 Dimensions Figure 1 RG501A and RG511A Dimensions 250 0234 rev 1 qxd 3 12 99 11 14 AM Page 2...
Страница 35: ...27 Block Diagram Figure 13 RG501A and RG511A Block Diagram 250 0234 rev 1 qxd 3 12 99 11 14 AM Page 27...
Страница 41: ...33 Notes 250 0234 rev 1 qxd 3 12 99 11 14 AM Page 33...
Страница 42: ...34 Notes 250 0234 rev 1 qxd 3 12 99 11 14 AM Page 34...