10
Installation
Mode select switches
Mode select switches, located on the logic board (see Figure 9), are preset
with switch 1 OFF and switch 2 ON. This allows you to operate the drive
without the use of limit switches. Change mode select switch settings
when power is off. Make sure that terminals 20, 21, and 22 are jumpered if
limit switches are not used. If limit switches are used, set the mode select
switches to one of the four operating modes:
Figure 9. Mode Select Switches
Mode Select Switches
Mode 1 (1 and 2 OFF) – Half cycle between forward and
reverse limit switches.
Mode 2 (1 ON and 2 OFF) – Single cycle between forward
and reverse limit switches.
Mode 3 (1 OFF and 2 ON) – Continuous cycle between
forward and reverse limit switches.
Mode 4 (1 and 2 ON) – Single cycle with one limit switch.
See page 14 for more information on limit switch operating modes.
250-0234 rev 1.qxd 3/12/99 11:14 AM Page 10