6
Installation
Cage-clamp terminals
RG Series drive connections are made to cage-clamp terminals. To insert a
wire into a terminal, see Figure 4.
1. Press down on the lever arm using a
small screwdriver.
2. Insert wire into the wire clamp.
3. Release the lever arm to clamp wire.
Figure 4. Cage-Clamp Terminal
Field fusing
To protect the motor field of shunt wound motors, all RG501A and
RG511A drives have 1.5A 3AG field fuses installed to fuseholder FU503
(see Figure 3). If this fuse needs to be replaced, use a fuse of the same
rating.
Figure 3. Line and Field Fuses
Line and Field Fuses
250-0234 rev 1.qxd 3/12/99 11:14 AM Page 6