Disposal
Staff: Adjuster Mechanic
✓
The vacuum pump is drained and cleaned.
•
Dismantle the vacuum pump and classify the materials.
•
Dispose of the materials properly.
TECHNICAL DATA
Service data
Sound pressure level (at 50 Hz, 80 mbar suction pressure, 1 m distance)
Model
S27
S52
S127
S162
S252
S327
Sound pressure level
64 dB(A)
70 dB(A)
70 dB(A)
73 dB(A)
72 dB(A)
69 dB(A)
Suction capacity
The operating data are applicable under the following conditions:
•
Conveyed product: dry air 20°C
•
Operating fluid: water 15°C
•
Compression pressure: 1 013 mbar (atmospheric pressure)
Suction capacity compared to suction pressure (10 % tolerance) at 50 Hz
(m³/h)
33
mbar
40
mbar
60
mbar
80
mbar
120
mbar
200
mbar
400
mbar
900
mbar
S27
5
8.5
13.5
16.5
20
23
24
24
S52
20
24
31
35
40
43
45
45
S127
36.5
46
59.5
66.5
73
79
82.5
79
S162
80
90
110
121
133
142
145
142
S252
107
125
150
165
180
190
192
184
S327
130
155
195
222
245
255
255
245
Suction capacity compared to suction pressure (10 % tolerance) at 60 Hz
(m³/h)
33
mbar
40
mbar
60
mbar
80
mbar
120
mbar
200
mbar
400
mbar
900
mbar
S27
5
9.5
19
23.5
28
32
34
31
S52
26
32
41.5
46.5
53
57
58
54
S127
44
56
77
86
93
99
102
94
S162
95
110
141
156
168
174
176
172
S252
120
145
184
205
220
230
235
225
S327
150
180
240
270
295
315
325
300
Electrical data
The electrical data is shown on the nameplate.
The operating data are applicable under the following conditions:
• Conveyed product: dry air 20°C
• Operating fluid : water 15°C
• Compression pressure: 1 013 mbar (atmospheric pressure)
Power requirement compared to suction pressure (10 % tolerance) at 50 Hz
(kW)
33
mbar
40
mbar
60
mbar
80
mbar
120
mbar
200
mbar
400
mbar
900
mbar
S27
0.6
0.6
0.65
0.7
0.75
0.82
0.85
0.55
S52
1.0
1.05
1.2
1.25
1.45
1.6
1.65
1.1
S127
2.2
2.2
2.45
2.55
2.8
3.0
3.1
2.25
S162
3.45
3.45
3.6
3.8
4.0
4.3
4.4
3.7
S252
4.2
4.2
4.4
4.6
5.0
5.4
5.6
4.8
S327
5.0
5.2
5.5
6.1
6.6
7.2
7.2
5.3
Power requirement compared to suction pressure (10 % tolerance) at 60 Hz
(kW)
33
mbar
40
mbar
60
mbar
80
mbar
120
mbar
200
mbar
400
mbar
900
mbar
S27
0.92
0.92
1.0
1.05
1.15
1.22
1.22
0.9
S52
1.55
1.6
1.75
1.85
2.0
2.2
2.3
1.8
S127
3.5
3.6
3.85
4.0
4.2
4.4
4.6
3.7
S162
4.2
4.3
4.6
4.8
5.1
5.5
5.7
4.8
S252
5.7
5.8
6.1
6.4
6.8
7.4
7.8
6.8
S327
7.8
7.9
8.4
8.9
9.5
10.2
10.5
7.5
Drive
Start frequency
≤
10 1/h
If the start and stop intervals are evenly distributed
Models
S27
S52
S127
S162
S252
S327
At 50 Hz
2 900 1/min
1450 1/min
At 60 Hz
3 500 1/min
1 750 1/min