ANTIGUA S27 / S52 / S127 / S162 / S252 / S327
520978-00
32
EN
MAINTENANCE PLAN
The applicable maintenance and service interval is the first period between the service interval and the use
period. Consult the manufacturer for other operating conditions. If the operating conditions of the operating
fluid (water temperature, pH value, carbonate hardness) are different, descale if necessary.
Few lime deposits
Operating conditions
•
Conveyed product air 20°C
•
Operating fluid
•
Fluid Water 15°C
• pH 6,5
to 8,0
•
Carbonate hardness 7°dH to 9°dH
Maintenance and service intervals
Component
Operation
Paragraph
Service interval per 1 000 h
0.2
2.5
5
20
Period of use in months
1
3
6
60
Vacuum pump
Clean
Maintenance / servicing
X
Vacuum pump
Descale
Operation
X
Seals
Check
Maintenance / servicing
X
Bearing
Check
Maintenance / servicing
X
Bearing
Replace
Consult manufacturer
X
Adjustment
fittings
Check
Installation manuals
X
Seals
Replace
Consult manufacturer
X
Significant lime deposits
Operating conditions
•
Conveyed product air 20°C
•
Operating fluid
•
Fluid Water 15°C
• pH 8,0
to 8,5
•
Carbonate hardness 7°dH to 9°dH
Maintenance and service intervals
Component
Operation
Paragraph
Service interval per 1 000 h
0.2
2.5
5
20
Period of use in months
1
3
6
60
Vacuum pump
Clean
Maintenance / servicing
X
Vacuum pump
Descale
Operation
X
Seals
Check
Maintenance / servicing
X
Bearing
Check
Maintenance / servicing
X
Bearing
Replace
Consult manufacturer
X
Adjustment
fittings
Check
Installation manuals
X
Seals
Replace
Consult manufacturer
X
FAULTS
Insufficient suction performance
Cause
Solution
Paragraph
Leaky suction duct
•
Check the connection on the suction side
and replace the seal if necessary
Maintenance / servicing
High operating
fluid temperature
•
Increase the flow of operating fluid.
•
Increase the fluid flow rate in the heat
exchanger
Installation manuals
Clogging of the
vacuum pump
•
Clean the liquid ring vacuum pump
and take corrective action if necessary
Maintenance / servicing
Squeaking (cavitation)
Cause
Solution
Paragraph
Suction pressures
too low
•
Connect the cavitation protection
•
Install a vacuum limiting valve when
operating in areas close to cavitation
Installation manuals
High operating
fluid temperature
•
Increase the flow rate of operating or
cooling fluid in the heat exchanger
Installation manuals
Abnormal operation
Cause
Solution
Paragraph
Operating fluid flow rate
too low
•
Adjust the operating fluid flow rate
Installation manuals
Loads on the pipe
system
•
Check the pipe connections
•
Check the connections of the pipes and the
operating fluid
Installation manuals
Air in the pipe
•
Chang the pipe routing
Installation manuals
Pump deformed /
misaligned
•
Check orientation and align if necessary
Installation
Resonance oscillations in
the pipe system
•
Check the pipe connections and fit a
compensator if necessary
Installation manuals
Unbalanced impeller
•
Contact the manufacturer.
Deposits on the impeller
•
Clean the vacuum pump
Maintenance / servicing