OM-286308 Page 16
5-7. Connecting 14-Pin Transceiver To Remote 14 Receptacle
Ref. 804746-B / Ref. 805627-A
!
Unexpected weld output can
cause electrical shock. Re-
mote controls can turn on
weld output from distant lo-
cations. Disconnect 14-Pin
Transceiver from remote 14
receptacle and remove the
batteries from the wireless
foot control and/or wireless
hand control before servic-
ing equipment.
Turn Off welding power source.
1
14-Pin Transceiver
2
Hand Threaded Nut
Insert the 14-Pin Transceiver into
the remote 14 receptacle on the
welding power source. Tighten the
Hand Threaded Nut by rotating
clockwise. Do not over tighten.
Turn welding power source on.
3
Wireless Status Light
Status Light Indication:
Solid Red = Not paired and/or lost
communication
Solid Green = Paired and communi-
cating
Solid Amber = Pairing mode,
searching for wireless remote
control
NOTICE
−
To remove the 14-Pin
Transceiver, rotate hand threaded
nut counterclockwise.
1
3
2
4
5-8. Wireless Foot Control Operation
!
Unexpected weld output can
cause electrical shock. Wire-
less remote controls can turn
weld output on from distant
locations. Disconnect receiv-
er from remote 14 receptacle
and remove battery from re-
mote control before servicing
equipment.
1
Remote Foot Control
Use control to turn on output
contactor and control amperage
remotely.
.
This control does not override
welding power source contactor
and amperage panel settings.
Welding power source panel
settings:
Place output contactor control in
remote position.
Place amperage control in Remote
position.
1
Ref. 805625-A