OM-261050 Page 48
10-8. Kubota D902 Engine Fault Code Guide
If a blink code is present, the engine
does not start or starts and then shuts
down in 10 seconds.
Engine errors will cause the engine to
shutdown. In Manual mode, the LED will
continue to blink until power is turned off
and back on. In Remote mode, the LED
blinks for approximately 5 seconds;
however, the error message associated
with the error flashes on the alpha
−
numer-
ic display for one minute.
If error message appears, consult
troubleshooting section for remedial
actions.
To erase the error message, press
and hold the Display Select push but-
ton on the Remote Panel until the dis-
play reads SYSTEMon and the En-
gine Error LED is off.
Multiple error codes will display one after
the other.
The blink pattern repeats as long as the
Engine Control switch is in Run.
Contact engine Factory Authorized
Service Agent if further assistance is
required to clear fault.
Table 10-1. Engine Error LED Blinking Pattern
Blinking Pattern
Symptom
Error Message
Remedy
—
= one long blink
-
= one short blink
— -
Engine over speed
OVErSPEEd
Check actuator.
— - -
Low oil pressure
LOW OIL
Check engine oil level.
Check engine oil pressure
using pressure gage.
Check low oil pressure
switch.
— - - -
Low battery voltage
NoCHARGE
Check alternator terminal L.
— - - - -
High coolant temperature
HiTEMP 1
Check water temperature
sender.
— - - - - - -
High coolant temperature
HiTEMP2
Check water temperature
sender.
— — -
Abnormal engine speed
SPd SENS
Check engine speed sensor.
— — - -
Engine does not run prop-
erly
GovCNTRL
Check actuator for current
problem.
— — - - - -
No coolant temperature sig-
nal
SEN OPEN
Check water temperature
sender for open
−
circuit.
— — - - - - -
Coolant temperature signal
always on
SENSHORT
Check water temperature
sender for short
−
circuit.
— — - - - - - -
Connection at alternator
terminal L open
ALTRNATR
Alternator disconnected at
terminal L.
— — - - - - - - -
Battery voltage too high
HiVOLTiN
Check alternator.
— — - - - - - - - -
Battery voltage too low
LOWbATT
Check alternator.
Содержание ENPAK
Страница 47: ...OM 261050 Page 43 10 2 Remote Panel Use With Section 10 3 248 998 1 2 6 3 4 5 7 8 9 10 11...
Страница 64: ...OM 261050 Page 60 SECTION 13 DIAGRAMS Figure 13 1 Training Circuit Diagram For EnPak...
Страница 65: ...OM 261050 Page 61 261 040 D...
Страница 66: ...OM 261050 Page 62 257 926 C Figure 13 2 EnPak Circuit Diagram...
Страница 67: ...OM 261050 Page 63 261 045 A Figure 13 3 Air Compressor Diagram...
Страница 69: ...OM 261050 Page 65 238 945 B1 Figure 13 6 Hydraulic Circuit Diagram Page 1 Models With Hydraulic Power Source...
Страница 79: ...OM 261050 Page 75 Notes...
Страница 94: ...OM 261050 Page 90 Notes...