OM-261050 Page 45
10-5. Operation And Error Messages
1
Alpha
−
Numeric Display
The following operational messages
may appear:
CHNG OIL
Indicates an oil change is needed. This light
flashes after the first 50 hours of operation
and then at normal oil change intervals
thereafter.
If CHECK ENGINE LED is on, engine oil
change time interval has counted down to
zero, indicating it is time to change engine
oil.
To reset display after oil change, see Sec-
tion 11-4.
If CHECK COMPRESSOR LED is on,
compressor oil change time interval has
counted down to zero, indicating it is time to
change compressor oil.
To reset display after oil change, see Sec-
HIGH SPd
Indicates engine is locked in high speed.
With engine running, press Power/Start
button to toggle speed.
AUTOSTOP
This will flash briefly when unit is in Auto On
mode and the engine stops automatically.
The following error messages may ap-
pear:
If error message appears, consult
troubleshooting section for remedial
actions.
Hi TEMP
Indicates high compressor temperature if
CHECK COMPRESSOR LED is on.
OVErPRES
Indicates the compressor has an over pres-
sure error.
OVErSPEEd
Indicates an engine over speed error.
LOW OIL
Indicates a low oil pressure condition in the
engine.
NoCHARGE
Indicates an alternator problem.
HiTEMP 1
Indicates high engine temperature if
CHECK ENGINE LED is on. The temperat-
ure switch has indicated high temperature.
HiTEMP 2
Indicates high engine temperature if
CHECK ENGINE LED is on. The temperat-
ure sensor has indicated high temperature.
SPd SENS
Indicates a problem with the engine speed
sensor.
GovCNTRL
Indicates a problem with the engine gov-
ernor control.
SEN OPEN
Indicates coolant sensor is open.
SENSHORT
Indicates coolant sensor is shorted.
ALTRNATR
Indicates an open condition in the alternat-
or.
HiVOLTiN
Indicates high input voltage from the bat-
tery.
LoVOLTiN
Indicates low input voltage from the battery.
ERROR
Indicates an engine error, and the error is
stored in memory. If the display is off, press
the Power push button once to activate the
Remote Panel. The display will read ER-
ROR and after a few seconds will flash an
error code. See Table 10-1.
To erase the error, press and hold the Dis-
play Select push button until the display
reads SYSTEMon, and the indicator is off.
The display will now cycle normally when
the Display Select push button is pushed.
ERROR1
Indicates problem with crane remote inter-
connecting cable, plug, receptacle, or ad-
apter harness.
ENVRT hot
Indicates the EnVerter power system is
overheated.
ENVRT ok
Indicates the EnVerter power system is
functioning. Press Power/Start button to
enable.
248 998
1
Содержание ENPAK
Страница 47: ...OM 261050 Page 43 10 2 Remote Panel Use With Section 10 3 248 998 1 2 6 3 4 5 7 8 9 10 11...
Страница 64: ...OM 261050 Page 60 SECTION 13 DIAGRAMS Figure 13 1 Training Circuit Diagram For EnPak...
Страница 65: ...OM 261050 Page 61 261 040 D...
Страница 66: ...OM 261050 Page 62 257 926 C Figure 13 2 EnPak Circuit Diagram...
Страница 67: ...OM 261050 Page 63 261 045 A Figure 13 3 Air Compressor Diagram...
Страница 69: ...OM 261050 Page 65 238 945 B1 Figure 13 6 Hydraulic Circuit Diagram Page 1 Models With Hydraulic Power Source...
Страница 79: ...OM 261050 Page 75 Notes...
Страница 94: ...OM 261050 Page 90 Notes...