OM-253 918 Page 39
5-16. Operator Point MIG Parameters Loading
Ref. 956142881_22-A
.
This setting is only available in
MIG mode. It allows the operat-
or to load and save desired
specified weld parameters and
recall them when required.
Store parameters:
Press and release P3 push buttons
simultaneously to enter the operat-
or point set-up menu. Use P3 push
buttons to select desired position
where parameters will be stored.
Press and hold Sequencer P2 push
button for about 10 seconds to save
parameters. Saving OK will be dis-
played on the digital meter. Press
and release process selection P1
push button to exit set-up menu.
Recall parameters:
Press and release P3 push buttons
simultaneously to enter the operat-
or point set-up menu. Use P3 push
buttons to select desired stored
parameters. Press and release Se-
quencer P2 push button to load
parameters.
P1
P3
P2
Press And Release
(Entering In Set-Up Menu)
Press And Hold
(Save Program)
Press And
Release
Press And
Release
Press And Release
(Loading A Program)
OR
Содержание MPi 220P
Страница 6: ......
Страница 51: ...OM 2253 918 Page 45 Notes...
Страница 52: ...OM 253 918 Page 46 SECTION 7 ELECTRICAL DIAGRAMS Figure 7 1 Circuit Diagram For Welding Power Source...
Страница 53: ...OM 2253 918 Page 47 956142882 B...