OM-253 918 Page 35
5-11. Synergic Pulsed MIG Welding Set-Up Menu
Ref. 956142881_14-A
To enter MIG welding set-up menu,
proceed as follows:
1
Sequencer Set-Up P2 Push
Button
2
Arc Length Control Knob
While in the set-up menu, use knob
to change sequencer parameters.
3
Sequencer
Adjustment/Operator Point
Setting P3 Push Buttons (See
Section 5-16)
4
Process Selection P1 Push
Button
Press and hold P2 push button to
enter the set-up menu. Sequencers
will be displayed on the digital meter
display. To change parameters, use
P3 push buttons or arc length con-
trol knob. To scroll through sequen-
cers, press and release P2 push
button. To exit set-up menu, press
and release process selection P1
push button. Desired parameters
will be stored.
5
Trigger Mode (2T/4T)
Use arc length control knob or se-
quencer adjustment P3 push but-
tons to change value (see Section
5-7).
6
Slope Time
Use Arc Length control knob to se-
lect amount of time that it takes to
slope up/down from initial amper-
age to weld amperage. To disable,
set to 0. When selected, use Arc
Length control knob or Sequencer
adjustment P3 push buttons to
change value, Default = 0.2
seconds (min = 0 sec, max = 1.5
sec).
7
Burnback Time (BBT)
This value is set to 1 second.
8
Postflow Time
Use Arc Length control knob to set
length of time gas flows after weld-
ing stops to protect the weld puddle.
When this item is selected, use the
Wire Feed Speed adjustment knob
to change value. Default = 0.3
seconds (min = 0 sec, max = 3 sec).
.
In Synergic Pulsed MIG, weld-
ing inductance cannot be set.
Press And Hold
1
4
2
3
SET-UP MENU
SCROLL THROUGH SEQUENCERS
Press And Release
1
2
3
2T
0.02S
1
5
6
7
0S
8