OM-253 918 Page 41
5-18. Basic Set-Up Menu Parameters Settings
Ref. 956142881_23-B
1
Power Switch
Use power switch to turn unit on.
When Miller appears on the display,
press and release sequencer
set-up P2 push button. Basic set-up
menu will be displayed.
2
Initial Wire Feed Speed
(WFS) Settings
Press and release P2 push button
to select desired parameter. Use
P3 push buttons to change value.
This value is either “reduced” or
“normal”. Default is set to “re-
duced”.
3
Wire Feed Speed (WFS) Unit
Of Measurement Settings
Press and release P2 push button
to select desired parameter. Use
P3 push buttons to change value.
Available units of measurement are
either MPM (meters per minute) or
IPM (inches per minute). Default is
set to “MPM”.
4
Voltage Reduction Device
(VRD) Settings
Press and release P2 push button
to select desired parameter. Use
P3 push buttons to change value.
This value is either “OFF” or “ON”.
Default is set to “ON”.
5
Digital Meter Display Setting
Press and release P2 push button
to select desired parameter. Use
P3 push buttons to change value.
This value is either “OFF” or “ON”.
Default is set to “ON”.
6
LCD Contrast Settings
Press and release P2 push button
to select desired parameter. Use
P3 push buttons to change value.
Default is set to “51” (min = 30, max
= 63).
Press and release process selec-
tion P1 push button to exit menu.
The next time the unit is turned on,
the latest settings will be retained.
.
To return to factory default set-
tings, see Section 5-14.
P1
P3
P2
Press And Release
(Entering In Set-Up Menu)
Press And
Release
Press And
Release
OR
(To Change Parameter)
H
L
RESETTING
See
Section 5-17
See
Section 5-17
2
3
4
5
6
1