OM-253 918 Page 36
5-12. 4T Trigger Set-Up Menu (Synergic Pulsed MIG Welding Only)
Ref. 956142881_15-A
To enter 4T trigger set-up menu:
Follow instructions listed in Section
5-7.
1
Postflow Time (See Section
5-11)
2
Arc Power (Hot Start)
Percentage
Percent increase of welding current
to make arc start easier. When this
item is selected, use the Arc Length
control knob or Sequencer adjust-
ment P3 push buttons to change
value. Default = 120% (min = 100%,
max = 150%).
3
Welding Current Percentage
Percent reduction of welding cur-
rent during the crater fill process.
When this item is selected, use the
Arc Length control knob or Sequen-
cer adjustment P3 push buttons to
change value. Default = 80% (min =
30%, max = 100%).
4
Slope Down Time
Time necessary for current de-
crease when using slope down
control. When this item is selected,
use the Arc Length control knob or
Sequencer adjustment P3 push
buttons to change value. Default =
0.5 seconds (min = 0.1 sec, max =
2.0 sec).
Press And Release
SET-UP MENU
SCROLL THROUGH PARAMETERS
Press And Release
3.0S
1
12.6%
2
3
48%
4
1.4S
Содержание MPi 220P
Страница 6: ......
Страница 51: ...OM 2253 918 Page 45 Notes...
Страница 52: ...OM 253 918 Page 46 SECTION 7 ELECTRICAL DIAGRAMS Figure 7 1 Circuit Diagram For Welding Power Source...
Страница 53: ...OM 2253 918 Page 47 956142882 B...