OM-253 918 Page 40
5-17. Rated Supply Current I
1
= 16 Amps Setting
Ref. 956142881_23-B
This setting allows the operator to
use the unit with a maximum of 16
amperes of rated supply current I
1
.
Before setting the rated supply cur-
rent I
1
,
!
Follow the Electromagnetic
Compatibility (EMC) inform-
ation according to Section
3-2.
!
Connect single phase input
power according to Section
4-11.
.
By setting a lower rated supply
current I
1
, the unit cannot have
the same performance then
that listed in Section 3-3 and
4-10 under normal operating
conditions.
1
Power Switch
Use power switch to turn unit on.
When Miller appears on the display,
press and release sequencer
set-up P2 push button. Unit is at de-
fault setting of H (high rated supply
current I
1
). Use sequencer para-
meters adjustment P3 push buttons
to set unit to L (low rated supply cur-
rent I
1
, max value =
−
16 amperes).
Press and release P2 to confirm
setting. Press and release process
selection P1 push button to exit
menu.
The next time the unit is turned on,
the latest settings will be retained.
.
To return to factory default set-
tings, see Section 5-14.
P1
P3
P2
Press And Release
(Entering In Set-Up Menu)
Press And
Release
Press And
Release
OR
(To Change Parameter)
H
L
1