6-10. Trigger Hold Feature
Ref. 242 929-C
1
Lit Indicator
The trigger hold feature is enabled
and disabled by pressing the
Trigger Hold Button. The Trigger
Hold Indicator Light indicates the
feature is on or off. An additional
trigger hold setting appears in the
TIMERS menu; the Trigger Hold
Delay, displayed as “HOLD”. The
HOLD time is the minimum amount
of time the trigger must be held for
the trigger hold to become active.
There is a built in maximum trigger
hold time which the trigger must be
released within for trigger hold to
become active. The maximum
trigger hold time is always 4.0
seconds after the Trigger Hold
Delay. For example, if the trigger
hold delay is set to 2.0 seconds,
and trigger hold window is from 2.0
to 6.0 seconds. If the trigger is
released inside this window the
weld will continue until the trigger is
pressed and released a second
time. If the trigger is released
outside this window (i.e. less than 2
seconds or more than 6 seconds)
the weld will stop immediately.
1
6-11. Trigger Hold Timing Chart