A complete Parts List is available at www.MillerWelds.com
OM-254915 Page 23
5-12. Selecting Input Voltage
803 539-C / 804 042-B
!
Turn Off welding power
source, disconnect input
power, and check voltage on
input capacitors according
to Section 7-6 before
proceeding.
.
Check input voltage available
at site.
.
Incorrect linking can damage
unit and void the warranty.
1
Voltage Selection View
Window
Check voltage selected in unit.
Changing selection is only neces-
sary if selected value does not
match available input voltage.
2
Relinking Board PC6
3
Mounting Screws
4
Receptacle RC23
(Connection For 230 VAC Or
208 VAC Input Power)
5
Receptacle RC46
(Connection For 460 VAC
Input Power)
Move relinking board as needed
and connect plug PLG32 (in unit) to
RC23 or RC46 according to input
power voltage.
Tools Needed:
5/16 in.
.
Be sure to reinstall all four screws
securing relinking board in place.
1
460V
5
230V
2
3
4
3