![Mikrotron EoSens 12CXP+ Скачать руководство пользователя страница 73](http://html1.mh-extra.com/html/mikrotron/eosens-12cxp/eosens-12cxp_reference-manual_1794708073.webp)
Analog Control
MIKROTRON GmbH
11 - 3
ColumnGain
Column gain will be increased before the analog value is converted
into a digital value. As a consequence the dynamic range will decrease
and noise will increase. In case your signal is too small, use column
gain before you use digital gain.
DigitalGain
When using digital gain the all pixels values of the image will be
increased. As a result, the whole image becomes brighter, the
dynamic range is decreased, and noise will be increased. It is recom-
mended to be used for 8-bit-images only.
Access
read/write
Type
integer
In
min: 0
Out
max: 3
Remark
column gain can be de-/incremented by:
gain0 = gain x 1 (default
gain1 = gain x 1.26
gain2 = gain x 1.87
gain3 = gain x 3.17
Access
read/write
Type
float
In
min: 1-10
Out
max: 1-10
Remark
column gain can be de-/incremented in steps of 0.25