Acquisition Control
MIKROTRON GmbH
5 - 8
AcquisitionFrameRateMax
This feature returns the highest possible frame rate in
[
Hz
]
.
Remark: This feature will
s o o n e x p i r e . U s e
AcquisitionFrameRate to
get the highest possible
frame rate.
TestImageSelector
This feature selects the type of test image sent by the camera.
Access
read
Type
unsigned integer
In
—
Out
max. frame rate
Remark
The max. frame rate depends on the defined frame size, the
used link speed, and the number of CoaXPress lines used for
image streaming.
Access
read/write
Type
enumeration
In
OFF
GreyHorizontal
Ramp
GreyDiagonal
HorizontalRamp
TestImageSelector is disabled
camera will send a test image that shows
vertically oriented gray scale bars moving
into horizontal direction on the screen
camera will send a test image that shows
diagonally oriented gray scale bars moving
on the screen into horizontal direction
Out
current test image selection
Remark
A connection reset sets the camera into normal operation mode.
Содержание EoSens 12CXP+
Страница 1: ...EoSens 12CXP Camera Reference Guide V1 2...
Страница 77: ...APPENDIX A Technical Data...
Страница 79: ...APPENDIX B Spectral Response...
Страница 81: ...Spectral Response MIKROTRON GmbH B 3 Image B 2 quantum efficiency curve for standard and NIR monochrome...
Страница 82: ...APPENDIX C Bayer Pattern...
Страница 85: ...APPENDIX D Camera Dimensions...
Страница 86: ...Camera Dimensions MIKROTRON GmbH D 2 Rear View Front View...
Страница 87: ...Camera Dimensions MIKROTRON GmbH D 3 Side View...