background image

22

  

TS571W Installation Instructions

TS571W Installation Instructions

  

23

This product has the ability of being control via a smart device (i.e. smartphone) with the addition of the MMS100 smart kit.  Refer to 
the instructions contained in the MMS100 kit or visit 

www.mightymule.com

 for more information

AUTO CLOSE SETTING

Optional Smart Control Setup

 

The auto close timer is set to OFF 
from the factory.

 

To set an auto close timer, use a 
small flat head screw driver to 
turn the auto close potentiometer 
clockwise.

 

The timer can be set from 
approximately 3 seconds to a 
maximum of 120 seconds.

••

••

•••

••

••

••

••

 

If you have additional accessories 
or external devices to install, see 
the following page.

 

Unless you have additional 
external accessories to install, 
your gate operator installation is 
now complete.

 

Please review the installation 
checklist at the end of this 
manual.

 

Use a phillips head screwdriver to 
close the control box.

Step 1

Step 2

Wiring Accessories through Control Board Wiring Knockout

Carefully remove wiring 
knockout plugs to insert 
accessory wires.

Open the control box cover.

Close the control box cover.

Insert accessory wires 
through the knockout and 
route to the accessory 
input terminals on the 
control board. (See pg. 12)

ON/OFF Switch

Accessory Wires
(Photo beams, keypad, etc.)

Mighty Mule strongly recommends the use of additional obstruction detection devices however we do not endorse any specific brand 
names. Only use products that are listed to be in compliance with any applicable UL safety standards and national and regional 
codes.

PLEASE NOTE: Contact sensors, non-contact sensors, shadow loops, etc. are not included with this product. Refer to the sensor 
manufacturer’s instructions for information about installing accessory devices. 

The Mighty Mule ONLY accepts accessory devices with normally open dry contact outputs.

Connecting Additional Devices

 WARNING

Make sure the operator power switch is turned OFF before connecting 

ANY device wiring to the terminals of the controller. Unplugging the 

transformer does not turn power to the operator off.

Содержание TS571W

Страница 1: ...Manual Leading Edge of the gate Photo Beam recommended not included Photo Beam recommended not included Sensing Edges recommended not included Vehicular Gate Gate Warning Sign Control Box TS571W PRINT...

Страница 2: ...ll to Open Operator Mounting Most Common 2 Installing the Closed Position Stop Plate Pull to Open 7 Push to Open Operator Mounting 8 Installing the Closed Position Stop Plate Push to Open 13 Control B...

Страница 3: ...an adjustable auto close feature After the gate reaches the fully open position it can be set to remain open up to 120 seconds before automatically closing Pressing the transmitter button at any time...

Страница 4: ...ey should be within sight of the gate located at least 10 feet from any moving part of the gate see diagram below Never install any control device where a user will be tempted to reach through the gat...

Страница 5: ...43 4283 and requesting a duplicate copy FOR THE INSTALLER AND END USER FOR THE INSTALLER AND END USER Mighty Mule gate operators utilize Dual Sense Technology entrapment protection Dual Sense Technolo...

Страница 6: ...tion and are required when installing Mighty Mule Automatic Gate Operators A minimum of two WARNING SIGNS must be installed in the area of the gate Each sign is to be visible by persons located on the...

Страница 7: ...e 3 12 v single gate 10 watts solar charger 8 16 26 12 v single gate 20 watts solar charger 14 28 38 12 v single gate 30 watts solar charger 20 44 54 Power increments are for reference only Low fricti...

Страница 8: ...uded Ground Ground 2 Inches or Less above ground Copper ground rod clamp Copper Single Conductor Lug 3 16 Drilled Pilot Hole 6 ft deep or more Metal gate post Metal Gate Post 12awg or Larger Gate Open...

Страница 9: ...Weatherproof cover for outdoor outlet and transformer If the post is larger than 6 bolts longer than 8 are needed ITEMS NOT INCLUDED TOOLS NEEDED Mechanical Installation ASSESSING THE GATE FOR INSTAL...

Страница 10: ...e recommended clearances TIP Turning the pivot bracket over gives more hole alignment options for the gate post pivot bracket assembly With the gate in the OPEN position use clamps to secure the opera...

Страница 11: ...re securely clamped Secure the post pivot bracket in place by installing the hardware shown Tighten both bolts O and Q Remove the gate post and gate brackets Use a hammer and center punch to mark the...

Страница 12: ...ence Post Remove the operator from the gate post and gate brackets With the gate fully open install the closed position stop plate hardware not included Do not fully tighten hardware until after the n...

Страница 13: ...ate Ensure that the operator is level With the operator arm temporarily secured to the gate check to ensure there is at least 2 inches of clearance between the operator arm and gate See illustration i...

Страница 14: ...OR MOUNTING PUSH TO OPEN OPERATOR MOUNTING Step 6 Step 5 Step 7 Step 8 Step 9 Secure the gate post bracket subassembly with the supplied hardware as shown Using a drill and 7 16 drill bit drill the ne...

Страница 15: ...N N S S Secure the gate bracket with the supplied hardware as shown Once the gate post and gate brackets are installed reattached the operator arm Ensure the operator arm is level adjusting the post...

Страница 16: ...ecurely tighten R OR R 3 Min 3 Min 4 Max Step 1 Step 2 Step 3 Note If you intend to install and use the MMS100 Wireless Connectivity System sold separately with your gate operator consider mounting yo...

Страница 17: ...er Access Connect the battery power wires Red to Red BAT and Black to Black BAT CONNECTING THE OPERATOR AND BATTERY TRANSFORMER OR SOLAR PANEL WIRING INSTALLATION WARNING Before digging contact local...

Страница 18: ...AUX SW1 SW2 PUSH 1 2 3 4 5 TERM6 GRN WHT BAT BAT GRN WHT BRN ORG BRN ORG RED BLK RED BLK AUX V AUX V PRIMARY SECONDARY SW1 SW2 TERM6 Battery Power Access From the other end of the low voltage wire st...

Страница 19: ...is preset from the factory to Low If your operator stops and reverses during a normal cycle follow the instructions below to change the Stall Force setting Adjusting the Stall Force 1 Press and hold t...

Страница 20: ...iring Accessories through Control Board Wiring Knockout Carefully remove wiring knockout plugs to insert accessory wires Open the control box cover Close the control box cover Insert accessory wires t...

Страница 21: ...OT apply external voltage inputs to these terminals All ACCESSORY INPUTS ITEMS 2 6 are connected with respect to the COMMON terminals ITEM 1 LOCK OUTPUTS ACCESSORY INPUTS CONTROL BOARD CONNECTIONS Pho...

Страница 22: ...struction detection devices if the unit works troubleshoot these devices h h Arm rev counter h h Arm power cable connections 1 beep every 10 seconds Low battery condition h h Check Fuses h h Battery H...

Страница 23: ...Connect battery batteries Visual Feedback Possible Diagnosis Check Solution The unit will not run 1 Unit arm travel limit not set 2 Transmitter not programmed 3 Power source issues 4 Arm problem h h...

Страница 24: ...f repair or replacement of your gate operator is necessary the Service Department will assign a Return Authorization RA number 5 Include a copy of your receipt and securely pack the component s author...

Страница 25: ...rity and Control unless otherwise indicated All rights are reserved by Nortek Security and Control and content may not be reproduced downloaded disseminated published or transferred in any form or by...

Страница 26: ...TER CODE on the MM136 keypad 1 2 3 4 is the default unless changed Once learned LED2 will flash and the buzzer will sound on the gate operator control board Proceed with installation of the MM136 per...

Страница 27: ...tallation Instructions Telephone Mighty Mule Sales 1 800 543 4283 Fax 850 575 8912 or Mighty Mule Technical Service 1 800 543 1236 Fax 850 575 8950 www mightymule com Copyright 2019 Nortek Security an...

Отзывы: