background image

8

  

TS571W Installation Instructions

TS571W Installation Instructions

  

9

PUSH-TO-OPEN OPERATOR MOUNTING

PUSH-TO-OPEN OPERATOR MOUNTING

G

V

T

O

L

G

11” 

S

S

E

F

B

N

N

G

V

T

O

L

G

11” 

S

S

E

F

B

N

N

Step 1

Step 2

 

Assemble the gate post bracket subassembly 
as shown with the Push-to-Open pivot bracket 
(FM148).  Must be purchased separate.

 

Attach the gate post bracket subassembly and 
gate bracket to the operator as shown.

Level 

horiz

onta

l cros

s me

mber

Level o

pener

Gate in Closed Position

Gate Bracket

Post Bracket Assembly

Step 3 

Step 4 

 

With the gate in the CLOSED 
position, use clamps to secure the 
operator to the gate post and center 
cross member of the gate.

 

Ensure that the operator is level.

 

With the operator arm temporarily 
secured to the gate, check to 
ensure there is at least 2 inches 
of clearance between the operator 
arm and gate. (See illustration in 
Step 4 below).

20”  MAX

CLEARANCE DIAGRAM

 

Disconnect the operator arm from the 
gate bracket.  

 

While supporting the operator, swing 
the gate and operator to the OPEN 
position.

 

Check for recommended clearances 
and binding as shown.

 

Ensure that the necessary arm stroke 
does not exceed 20 inches.

 

Make adjustments to the 
mounting brackets to achieve the 
recommended clearances. 
 

TIP:

 Turning the pivot bracket over 

gives more hole alignment options for 
the gate post pivot bracket assembly.

Your Property

Your Property

Push-to-Open pivot 
bracket (FM148)

Содержание TS571W

Страница 1: ...Manual Leading Edge of the gate Photo Beam recommended not included Photo Beam recommended not included Sensing Edges recommended not included Vehicular Gate Gate Warning Sign Control Box TS571W PRINT...

Страница 2: ...ll to Open Operator Mounting Most Common 2 Installing the Closed Position Stop Plate Pull to Open 7 Push to Open Operator Mounting 8 Installing the Closed Position Stop Plate Push to Open 13 Control B...

Страница 3: ...an adjustable auto close feature After the gate reaches the fully open position it can be set to remain open up to 120 seconds before automatically closing Pressing the transmitter button at any time...

Страница 4: ...ey should be within sight of the gate located at least 10 feet from any moving part of the gate see diagram below Never install any control device where a user will be tempted to reach through the gat...

Страница 5: ...43 4283 and requesting a duplicate copy FOR THE INSTALLER AND END USER FOR THE INSTALLER AND END USER Mighty Mule gate operators utilize Dual Sense Technology entrapment protection Dual Sense Technolo...

Страница 6: ...tion and are required when installing Mighty Mule Automatic Gate Operators A minimum of two WARNING SIGNS must be installed in the area of the gate Each sign is to be visible by persons located on the...

Страница 7: ...e 3 12 v single gate 10 watts solar charger 8 16 26 12 v single gate 20 watts solar charger 14 28 38 12 v single gate 30 watts solar charger 20 44 54 Power increments are for reference only Low fricti...

Страница 8: ...uded Ground Ground 2 Inches or Less above ground Copper ground rod clamp Copper Single Conductor Lug 3 16 Drilled Pilot Hole 6 ft deep or more Metal gate post Metal Gate Post 12awg or Larger Gate Open...

Страница 9: ...Weatherproof cover for outdoor outlet and transformer If the post is larger than 6 bolts longer than 8 are needed ITEMS NOT INCLUDED TOOLS NEEDED Mechanical Installation ASSESSING THE GATE FOR INSTAL...

Страница 10: ...e recommended clearances TIP Turning the pivot bracket over gives more hole alignment options for the gate post pivot bracket assembly With the gate in the OPEN position use clamps to secure the opera...

Страница 11: ...re securely clamped Secure the post pivot bracket in place by installing the hardware shown Tighten both bolts O and Q Remove the gate post and gate brackets Use a hammer and center punch to mark the...

Страница 12: ...ence Post Remove the operator from the gate post and gate brackets With the gate fully open install the closed position stop plate hardware not included Do not fully tighten hardware until after the n...

Страница 13: ...ate Ensure that the operator is level With the operator arm temporarily secured to the gate check to ensure there is at least 2 inches of clearance between the operator arm and gate See illustration i...

Страница 14: ...OR MOUNTING PUSH TO OPEN OPERATOR MOUNTING Step 6 Step 5 Step 7 Step 8 Step 9 Secure the gate post bracket subassembly with the supplied hardware as shown Using a drill and 7 16 drill bit drill the ne...

Страница 15: ...N N S S Secure the gate bracket with the supplied hardware as shown Once the gate post and gate brackets are installed reattached the operator arm Ensure the operator arm is level adjusting the post...

Страница 16: ...ecurely tighten R OR R 3 Min 3 Min 4 Max Step 1 Step 2 Step 3 Note If you intend to install and use the MMS100 Wireless Connectivity System sold separately with your gate operator consider mounting yo...

Страница 17: ...er Access Connect the battery power wires Red to Red BAT and Black to Black BAT CONNECTING THE OPERATOR AND BATTERY TRANSFORMER OR SOLAR PANEL WIRING INSTALLATION WARNING Before digging contact local...

Страница 18: ...AUX SW1 SW2 PUSH 1 2 3 4 5 TERM6 GRN WHT BAT BAT GRN WHT BRN ORG BRN ORG RED BLK RED BLK AUX V AUX V PRIMARY SECONDARY SW1 SW2 TERM6 Battery Power Access From the other end of the low voltage wire st...

Страница 19: ...is preset from the factory to Low If your operator stops and reverses during a normal cycle follow the instructions below to change the Stall Force setting Adjusting the Stall Force 1 Press and hold t...

Страница 20: ...iring Accessories through Control Board Wiring Knockout Carefully remove wiring knockout plugs to insert accessory wires Open the control box cover Close the control box cover Insert accessory wires t...

Страница 21: ...OT apply external voltage inputs to these terminals All ACCESSORY INPUTS ITEMS 2 6 are connected with respect to the COMMON terminals ITEM 1 LOCK OUTPUTS ACCESSORY INPUTS CONTROL BOARD CONNECTIONS Pho...

Страница 22: ...struction detection devices if the unit works troubleshoot these devices h h Arm rev counter h h Arm power cable connections 1 beep every 10 seconds Low battery condition h h Check Fuses h h Battery H...

Страница 23: ...Connect battery batteries Visual Feedback Possible Diagnosis Check Solution The unit will not run 1 Unit arm travel limit not set 2 Transmitter not programmed 3 Power source issues 4 Arm problem h h...

Страница 24: ...f repair or replacement of your gate operator is necessary the Service Department will assign a Return Authorization RA number 5 Include a copy of your receipt and securely pack the component s author...

Страница 25: ...rity and Control unless otherwise indicated All rights are reserved by Nortek Security and Control and content may not be reproduced downloaded disseminated published or transferred in any form or by...

Страница 26: ...TER CODE on the MM136 keypad 1 2 3 4 is the default unless changed Once learned LED2 will flash and the buzzer will sound on the gate operator control board Proceed with installation of the MM136 per...

Страница 27: ...tallation Instructions Telephone Mighty Mule Sales 1 800 543 4283 Fax 850 575 8912 or Mighty Mule Technical Service 1 800 543 1236 Fax 850 575 8950 www mightymule com Copyright 2019 Nortek Security an...

Отзывы: