background image

viii

  

TS571W Installation Instructions

TS571W Installation Instructions

  

ix

Product identification label (1) installed on the side of the Control box.

Labels (1) installed on the front of control box

Control arm label (2) installed on operator arm

mightymule.com

MM571W

10019674A

1. 

KEEP CLEAR!

 Gate may move at any time.

2.  Read all SAFETY INSTRUCTIONS in the user’s manual.

3.  Do not allow children to operate gate or play in gate area.

4.  This gate is for vehicles only. Pedestrians must use separate entrance.

Moving gate can cause injury or death!

1.  TENEZ-VOUS LOIN!

 La barrière peut se déplacer à tout moment.

2.  Lisez toutes les instructions de sécurité dans le manuel de l'utilisateur.

3.  Ne laissez pas les enfants utiliser la barrière ou jouer à proximité de la barrière.

4.  Cette barrière est uniquement réservée aux véhicules. Les piétons doivent 

utiliser une autre entrée.

AVERTISSEMENT

WARNING

La barrière en mouvement peut provoquer des 

blessures graves ou la mort!

10019665A

GEN7 SERIES

 – DC Swing Gate Operator

P/N MM571W

Conforms to UL STD 325 • Certified to CSA STD C22.2 No.247
Maximum Gate: 300 lb. (136 kg); 12 ft. (3.65 m)
Voltage: 12 Vdc; Frequency: 0 Hz; Power: 25 W

Class I Vehicular Gate

S/N: YYYYMMDDx0000

Nortek Security & Control – Carlsbad, CA USA

E472888

Warning Sign

 Pedestrian Gate

Pedestrian Gate Lock

(recommended, not included) 

7 foot

minimum

Control Box

Vehicular Gate

Important Safety Information

Important Safety Information

Warning signs alert people of automatic gate operation and are required when installing Mighty Mule Automatic Gate Operators. A 
minimum of two WARNING SIGNS must be installed in the area of the gate. Each sign is to be visible by persons located on the side 
of the gate on which the placard is installed.
The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access 
opening. The pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that persons will not 
come in contact with the vehicular gate during the entire path of travel of the vehicular gate.
We recommend using the Bulldog Pedestrian Gate Lock (Call the Nortek Security and Control Sales Department at 800-543-4283) 
for controlled access.

INSTALLING WARNING SIGNS AND PEDESTRIAN GATES

Warning Signs

The gate operator is provided with two safety warning signs. 
The signs 

MUST

 be installed on the front and back of the gate where they will be visible in the area of 

the gate.
Permanently secure each warning sign to the gate.
Immediately replace a damaged, eligible or missing warning sign.
Call Customer Service at 800-543-4283 for a free replacement.

!

These warning labels should be found at the locations specified below. If any of them are missing, immediately contact 
Nortek Security and Control for replacements.

REQUIRED SAFETY PRECAUTIONS FOR GATES

Example of TS571W Installation

(Installations vary slightly on different types of gates)

Содержание TS571W

Страница 1: ...Manual Leading Edge of the gate Photo Beam recommended not included Photo Beam recommended not included Sensing Edges recommended not included Vehicular Gate Gate Warning Sign Control Box TS571W PRINT...

Страница 2: ...ll to Open Operator Mounting Most Common 2 Installing the Closed Position Stop Plate Pull to Open 7 Push to Open Operator Mounting 8 Installing the Closed Position Stop Plate Push to Open 13 Control B...

Страница 3: ...an adjustable auto close feature After the gate reaches the fully open position it can be set to remain open up to 120 seconds before automatically closing Pressing the transmitter button at any time...

Страница 4: ...ey should be within sight of the gate located at least 10 feet from any moving part of the gate see diagram below Never install any control device where a user will be tempted to reach through the gat...

Страница 5: ...43 4283 and requesting a duplicate copy FOR THE INSTALLER AND END USER FOR THE INSTALLER AND END USER Mighty Mule gate operators utilize Dual Sense Technology entrapment protection Dual Sense Technolo...

Страница 6: ...tion and are required when installing Mighty Mule Automatic Gate Operators A minimum of two WARNING SIGNS must be installed in the area of the gate Each sign is to be visible by persons located on the...

Страница 7: ...e 3 12 v single gate 10 watts solar charger 8 16 26 12 v single gate 20 watts solar charger 14 28 38 12 v single gate 30 watts solar charger 20 44 54 Power increments are for reference only Low fricti...

Страница 8: ...uded Ground Ground 2 Inches or Less above ground Copper ground rod clamp Copper Single Conductor Lug 3 16 Drilled Pilot Hole 6 ft deep or more Metal gate post Metal Gate Post 12awg or Larger Gate Open...

Страница 9: ...Weatherproof cover for outdoor outlet and transformer If the post is larger than 6 bolts longer than 8 are needed ITEMS NOT INCLUDED TOOLS NEEDED Mechanical Installation ASSESSING THE GATE FOR INSTAL...

Страница 10: ...e recommended clearances TIP Turning the pivot bracket over gives more hole alignment options for the gate post pivot bracket assembly With the gate in the OPEN position use clamps to secure the opera...

Страница 11: ...re securely clamped Secure the post pivot bracket in place by installing the hardware shown Tighten both bolts O and Q Remove the gate post and gate brackets Use a hammer and center punch to mark the...

Страница 12: ...ence Post Remove the operator from the gate post and gate brackets With the gate fully open install the closed position stop plate hardware not included Do not fully tighten hardware until after the n...

Страница 13: ...ate Ensure that the operator is level With the operator arm temporarily secured to the gate check to ensure there is at least 2 inches of clearance between the operator arm and gate See illustration i...

Страница 14: ...OR MOUNTING PUSH TO OPEN OPERATOR MOUNTING Step 6 Step 5 Step 7 Step 8 Step 9 Secure the gate post bracket subassembly with the supplied hardware as shown Using a drill and 7 16 drill bit drill the ne...

Страница 15: ...N N S S Secure the gate bracket with the supplied hardware as shown Once the gate post and gate brackets are installed reattached the operator arm Ensure the operator arm is level adjusting the post...

Страница 16: ...ecurely tighten R OR R 3 Min 3 Min 4 Max Step 1 Step 2 Step 3 Note If you intend to install and use the MMS100 Wireless Connectivity System sold separately with your gate operator consider mounting yo...

Страница 17: ...er Access Connect the battery power wires Red to Red BAT and Black to Black BAT CONNECTING THE OPERATOR AND BATTERY TRANSFORMER OR SOLAR PANEL WIRING INSTALLATION WARNING Before digging contact local...

Страница 18: ...AUX SW1 SW2 PUSH 1 2 3 4 5 TERM6 GRN WHT BAT BAT GRN WHT BRN ORG BRN ORG RED BLK RED BLK AUX V AUX V PRIMARY SECONDARY SW1 SW2 TERM6 Battery Power Access From the other end of the low voltage wire st...

Страница 19: ...is preset from the factory to Low If your operator stops and reverses during a normal cycle follow the instructions below to change the Stall Force setting Adjusting the Stall Force 1 Press and hold t...

Страница 20: ...iring Accessories through Control Board Wiring Knockout Carefully remove wiring knockout plugs to insert accessory wires Open the control box cover Close the control box cover Insert accessory wires t...

Страница 21: ...OT apply external voltage inputs to these terminals All ACCESSORY INPUTS ITEMS 2 6 are connected with respect to the COMMON terminals ITEM 1 LOCK OUTPUTS ACCESSORY INPUTS CONTROL BOARD CONNECTIONS Pho...

Страница 22: ...struction detection devices if the unit works troubleshoot these devices h h Arm rev counter h h Arm power cable connections 1 beep every 10 seconds Low battery condition h h Check Fuses h h Battery H...

Страница 23: ...Connect battery batteries Visual Feedback Possible Diagnosis Check Solution The unit will not run 1 Unit arm travel limit not set 2 Transmitter not programmed 3 Power source issues 4 Arm problem h h...

Страница 24: ...f repair or replacement of your gate operator is necessary the Service Department will assign a Return Authorization RA number 5 Include a copy of your receipt and securely pack the component s author...

Страница 25: ...rity and Control unless otherwise indicated All rights are reserved by Nortek Security and Control and content may not be reproduced downloaded disseminated published or transferred in any form or by...

Страница 26: ...TER CODE on the MM136 keypad 1 2 3 4 is the default unless changed Once learned LED2 will flash and the buzzer will sound on the gate operator control board Proceed with installation of the MM136 per...

Страница 27: ...tallation Instructions Telephone Mighty Mule Sales 1 800 543 4283 Fax 850 575 8912 or Mighty Mule Technical Service 1 800 543 1236 Fax 850 575 8950 www mightymule com Copyright 2019 Nortek Security an...

Отзывы: