Navn CoWelder™
Produkt UR10E-PI350
Version
A – 1.5.2021
Udfærdiget af:
CTM
72
7.3
Function Tests
7.3.1 Test Safety Function
Interval: Monthly
1. Press the emergency stop
2. Observe the robot stops and shuts off power to the joints
3. Power on robot again
Important
Check emergency stops separately. In case of defects, stop the machine
immediately and make sure that it cannot restart.
7.3.2 Test Freedrive
Interval: Yearly
1. Unmount attachment or set TCP/Payload/CoG according to tool specifications
2. Monitor that the robot maintains its position
3. Move the robot to a horizontally elongated position and release
4. Verify the robot can maintain its position when not being held with the Freedrive button still
pressed