20
Any 2 Tones Tone Times Fields
Note that this format is provided to support PLECTRON and other formats which do not conform to a
standardized code plan.
1
st
Tone Time field
Enter the duration of the 1
st
tone in milliseconds. In the PLECTRON fast format, this is 750 ms. All 4 digits
must be entered.
Range:
0000 to 9999 milliseconds
2
nd
Tone Time field
Enter the duration of the 2
nd
tone in milliseconds. In the PLECTRON fast format, this is 250 ms. All 4 digits
must be entered.
Range:
0000 to 9999 milliseconds
DTMF Tone Times Fields
On Time field
Enter the tone on-time. All 4 digits must be entered.
Range:
0000 to 9999 milliseconds
Gap Time field
Enter the gap time between tones. All 4 digits must be entered.
Range:
0000 to 9999 milliseconds
Pager Profiles and Defaults
The following shows the factory default pager profile settings that allow the TRC-1000 to function ‘out of the
box’. Please refer to section
Error! Reference source not found.
for more information.
Profile 1:
The factory default settings for this profile are as follows:
Profile Name:
PULSE
2805
Pager Type:
Pulse
Tone
Format:
2805
Make Time:
0040
Tail Time:
1000
Profile 2:
The factory default settings for this profile are as follows:
Profile Name:
REACH
2-TONE
Pager Type:
2-Tone
Format:
REACH
1
st
Tone Time:
2000
2
nd
Tone Time:
0700
Profile 3:
The factory default settings for this profile are as follows:
Profile Name:
MOT
GENERAL
Pager Type:
2-Tone
Format:
MOT
GENERAL
1
st
Tone Time:
1000
2
nd
Tone Time:
3000
Profile 4:
The factory default settings for this profile are as follows:
Profile Name:
DTMF
Pager Type:
DTMF
On Time:
0050
Off Time:
0050