Hang Time:
Low-level guard tone will continue to be sent for this much time after encoding is completed. This
gives the operator time to say a brief voice message, or to press SEND before the guard tone drops. Hang
time does not apply when unless making a encoding.
Range:
0000 to 9990 milliseconds
Default: 0000
milliseconds
Func Display:
Turning on this option causes the last selected function to be displayed every 2 seconds on
the bottom line of the display when in Control Mode. This option applies only when there is a distinction
between frequency and function in your application.
U
OFF
U
Disable function display.
ON
Enable function display.
Fast Scrolling:
Fast Scrolling allows for faster navigation through the menu system. When this setting is
turned off, menu items will appear to scroll from side-to-side. This provides positive feedback in response to
scrolling through menus. If this effect is desired, Fast Scrolling can be disabled.
OFF
Scroll slowly to give side-to-side effect.
U
ON
U
Scroll at fast speed.
Contrast :
Allows the display contrast to be adjusted for best viewing.
U
LOW
U
Low contrast setting.
HIGH High
contrast
setting.
Timeout Timer:
Prevents the transmitter from being keyed indefinitely if the SEND key is stuck or
unintentionally in the depressed position. The TRC will cease sending low-level guard tone and disable the
line driver after the amount of time programmed by this setting. This timer also applies to the INTER key. If set
to 00, the timeout timer feature will be disabled. Both digits must be entered.
Range:
00 to 99 seconds
Default: 00
seconds
Handset Enable:
Selects which type of microphone is attached to the TRC. Be sure to set jumpers
accordingly.
U
OFF
U
Internal or gooseneck style microphone.
ON External
handset.
Off-hook Mon:
If enabled, the TRC will automatically transmit the Monitor Function sequence as per FCC
requirements when the operator picks up an externally attached handset. For privately owned systems this
option can be disabled. The External Handset Option must be enabled for this setting to be recognized.
U
OFF
U
Do not transmit the monitor sequence when the handset goes off-hook.
ON
Automatically transmit the monitor sequence when the handset goes off-hook.
Line 2/Sup Opt:
If the line-2/supervisor relay is installed, this setting must be enabled for the feature to work.
U
OFF
U
Line 2 or supervisor option disabled.
ON
Line 2 or supervisor option enabled.
Follow Decode:
Not used in the TRC-1000.
Printer Option:
The TRC, if ordered with the printer cable option, can log the pages to a serial device. The
printer must have a print buffer and a standard RS-232 port. It must be configured for 9600 baud, 8 data bits,
1 stop bit and no parity. In order to send data to the printer, this option must be on.
U
OFF
U
Do not send data to printer
ON
Send data to printer
Trunk Mode:
The TRC, if ordered with the TRC Option F, can work on a 4-wire system for hearing trunking
proceed tones. Turning this field to ON changes the KEYUP DELAY to a time to wait for the trunking proceed
tones before the dispatcher can talk.
U
OFF
U
Keyup
Delay
ON
Trunking Delay Time