PAGER SETUP <6>
This section allows you define up to 10 different pager types. There are 10 pager profiles consisting of the
fields described below. Each profile has a factory default setting intended as examples to follow.
Profile Name field:
This can be any alphanumeric string up to 14 characters. The name can be chosen
based on the pager description such as ‘MOT PLAN L’ or ‘CCIR. When a user is added to the database, you
will be able to scroll through the 10 profile names and select the appropriate one.
Pager Type field:
Select the basic pager type. You will then be prompted for more information based on the
pager type. The following pager types are available:
2-Tone, 5-Tone, Pulse Tone, Any 2 tones, DTMF
Format and Tone Times fields for 2-Tone
Select the format matching the pager from among the following:
AVCALL/QC1 2+2, GE, REACH, MOT GENERAL, MOTOROLA A, B, C, D, E, F, G, H, J, K, M, N, P, Q, R,
S, T, U, V, W
1
st
Tone Time field
Enter the duration of the 1
st
tone in milliseconds. For Motorola pagers, this is typically 1 seconds (1000
milliseconds). All 4 digits must be entered.
Range:
0000 to 9999 milliseconds
2
nd
Tone Time field
Enter the duration of the 2
nd
tone in milliseconds. For Motorola pagers, this is typically 3 second (3000
milliseconds). All 4 digits must be entered.
Range:
0000 to 9999 milliseconds
Format and Tone Times fields for 5/6-Tone
Select the format matching the pager from among the following:
EIA, EUROSIGNAL, ZVEI, DZVEI, DDZVEI, CCIR, EEA, NATEL, MODAT
1
st
Tone Time field
Enter the duration of the 1
st
tone in milliseconds. For EIA pagers, this is typically 33 milliseconds. All 4 digits
must be entered.
Range:
0000 to 9999 milliseconds
N
th
Tone Time field
Enter the duration of for each of the tones that follow the 1
st
tone in milliseconds. For EIA pagers, this is
typically 33 milliseconds. All 4 digits must be entered.
Range:
0000 to 9999 milliseconds
Format and Tone Times fields for Pulse Tone
Choose the tone frequency.
2805 or 1500
Make Time field
Enter the make time (on-time) of each pulse. The ‘break’ time (off-time) will automatically be set for 1.5 times
the make time. For example, if the make time is 40 ms, the break time is 60 ms. All 4 digits must be entered.
Range:
0000 to 9999 milliseconds
Tail Time field
Enter the duration that tone should remain on after dialing. All 4 digits must be entered.
Range:
0000 to 9999 milliseconds