17
SETUP menu
SET DATE/TIME <2>
In order for the correct date and time to be displayed, the real-time clock must be set.
Date: MMDDYYYY
Time: HHMMSS
SPEED DIAL SET <3>
Speed Dial feature:
When in Control Mode, the number keys <1> through <9> may be turned into speed dial
keys by enabling this feature.
U
OFF
U
Speed dialing disabled.
ON
Speed dialing enabled.
Speed Dial 1-9:
To associate a unit to a speed dial number, it must be in the user database. For each speed
dial entry, simply locate the user in the database in the same manner as if placing a call to a unit.
Range: 0-14
characters
Default: blank
SOUNDS SETUP <4>
Keypad Beep:
Turning this option on causes a beep to be heard for each key press.
OFF
Keypad beeps off
U
ON
U
Keypad beeps on
Go-ahead Beep:
When using the TRC as an encoder, it will take some time for the signaling to take place.
The operator must wait for this time to elapse before speaking or he/she will not be heard. The go-ahead
beep alerts the operator when the signaling is complete so they will know when it is okay to begin speaking.
U
OFF
U
Disable go-ahead beep.
ON
Enable go-ahead beep.
Cross Mute:
If using more than one TRC in the same room, feedback (howling) may occur if one unit is
transmitting while another is listening. Enabling Cross Mute prevents this from happening by muting the
internal speaker whenever guard tone is detected.
U
OFF
U
Cross Mute disabled.
ON
Cross Mute enabled.
Auto Mute time:
Specifies the amount of time after guard tone is detected that the internal speaker will be
muted. This facilitates muting of the function tone and/or signaling tones generated by parallel remotes. All
four digits must be entered. If 0000 is entered, the feature is disabled.
Range:
0000 to 9999 milliseconds
Default: 0000
milliseconds
CONSOLE SETUP menu <5>
Data Entry Mode:
Determines if numeric entry or alphanumeric data entry is the default mode when placing a
call. The mode of entry can also be toggled by pressing the MENU key during data entry. Enable
alphanumeric mode only after entering names and numbers in the user database.
U
NUMERIC
U
Start in numeric only mode.
ALPHA
Start entry in alphanumeric mode.
Key-Up Delay:
This is the amount of time the TRC will wait after sending guard and function tone before
sending the encode sequence over the air. This time allows for delays introduced by repeaters and decoding
of squelch control signals such as CTCSS.
Range:
0005 to 9999 milliseconds
Default: 0100
milliseconds