Maintenance and
Disassembly
Page 66
MOD01-23HFN1-MT0W
Procedure
Illustration
1) Remove the connector for the
compressor (see
CJ_ODU_INV_016).
2) Pull out the two blue wires connected
with the four way valve (see
CJ_ODU_
INV_016).
3) Pull out connectors of the condenser
coil temp. sensor(T3),outdoor ambient
temp. sensor(T4) and discharge temp.
sensor(TP) (see
CJ_ODU_INV_016).
4) Disconnect the electronic expansion
valve wire (see Fig
CJ_ODU_INV_016).
5) Remove the connector for the reactor
(see Fig
CJ_ODU_INV_016).
6) Then remove the electronic control
box.
CJ_ODU_INV_016
Note: This section is for reference only. Actual unit appearance may vary.
Содержание MISSION2 3D INVERTER Series
Страница 1: ...MISSION2 3D INVERTER SERIES SM_MISSION2 GA _60R410A_3D INVERTER_US_NA_171121 2017 SERVICE MANUAL...
Страница 2: ......
Страница 4: ......
Страница 11: ...Specifications Page 7 MOB01 09HFN1 MW0W MOB01 12HFN1 MV0W MOCA01 18HFN1 MT0W...
Страница 12: ...Specifications Page 8 MOD01 23HFN1 MT0W...
Страница 15: ...Specifications Page 11 PCB board of MOD01 23HFN1 MT0W...
Страница 16: ...Specifications Page 12 IPM board of MOD01 23HFN1 MT0W...
Страница 101: ...Troubleshooting Page 97 Remark Measure the DC voltage between P and N port The normal value should be around 310V...