Service manual for Wash and Dry Combo product
Midea America Company
-------------------------------------------------------------------------------------------------------------------------------------------------------
-
11
-
Drain Pump Filter
According to the soil level within the cycles and the frequency of the cycles, you have to inspect
and clean the filter regularly.
The pump should be inspected if the machine does not empty or no spin;
The machine makes an unusual noise during draining due to objects such as safety pins, coins
etc. blocking the pump.
The Service panel proceed as follows:
1. After the power is dis-connected, open the filter cover by hand
2. Turn the filter down as shown with the figure and take out sundries matters.
3. Reinstall each part back after sundries matters are removed.
Warning!
When the appliance is in use and depending on the program selected . There can be hot water in the
pump. Never remove the pump cover during a wash cycle, always wait until the appliance has finished
the cycle, and is empty. When replacing the cover, ensure it is securely installed.