Service manual for Wash and Dry Combo product
Midea America Company
-------------------------------------------------------------------------------------------------------------------------------------------------------
-
17
-
E10
doesn’t
change with
valves open
valve and stop
with Error
code display
Water level
sensor or
control switch
(No voltage on
the water inlet
valve)
A water lever control switch
controls how much water enters
the washing machine by PCB. If
the water level control switch is
defective, or more commonly, if
the small air pipe attached to the
air bell restricted, The switch will
not be able to close the electrical
contacts to the washer fill valve.
CHECK THE AIR PIPE
CHECK THE WATER LEVERL
SENSOR
CHECK THE PCB and the inner
wire between PCB and the sensor