Service manual for Wash and Dry Combo product
Midea America Company
-------------------------------------------------------------------------------------------------------------------------------------------------------
-
32
-
The unit doesn’t operate drying or clothes not dry enough. (E37, E38, E3A)
The unit doesn’t operate drying
or clothes not dry enough.
(E37, E38, E3A)
Check if the drum rotates
If not, refer to
Drum non-rotating
Check the water inlet (
E10
)
Replace the cold water valve which includes the valve for
drying water inlet if failed.
Check the manual temperature
sensor for jumped off
Push it ON if jumped.
Normal resistance: less than 5mΩ
Open circuit temperature: 165 +/- 5
℃
(329 +/- 9 F)
Check all wires connected
Drying Heater assembly.
Include wires to all temperature
sensors, heaters, Fan Flange, and
PCBs. Replace the harness if failure.
Check the temperature sensor as table next page.
Check the drying heater
The Resistance should be in range from 8
to 15Ω.
Check the Fan Flange and
capacitor. Replace if failure.
The resistance of main coil (blue and black
wires) should be in range from 80 to 1
10Ω.
The resistance of vice coil (blue and brown
wires) should be in range from 90 to 1
20Ω.
The capacitor should be in range 2.5uf +/- 5%.